Publication:
Dense, shape‐optimized posterior 32‐channel coil for submillimeter functional imaging of visual cortex at 3T

Thumbnail Image

Open/View Files

Date

2015

Published Version

Journal Title

Journal ISSN

Volume Title

Publisher

John Wiley and Sons Inc.
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Farivar, Reza, Filip Grigorov, Andre J. van der Kouwe, Lawrence L. Wald, and Boris Keil. 2015. “Dense, shape‐optimized posterior 32‐channel coil for submillimeter functional imaging of visual cortex at 3T.” Magnetic Resonance in Medicine 76 (1): 321-328. doi:10.1002/mrm.25815. http://dx.doi.org/10.1002/mrm.25815.

Research Data

Abstract

Purpose Functional neuroimaging of small cortical patches such as columns is essential for testing computational models of vision, but imaging from cortical columns at conventional 3T fields is exceedingly difficult. By targeting the visual cortex exclusively, we tested whether combined optimization of shape, coil placement, and electronics would yield the necessary gains in signal‐to‐noise ratio (SNR) for submillimeter visual cortex functional MRI (fMRI). Method We optimized the shape of the housing to a population‐averaged atlas. The shape was comfortable without cushions and resulted in the maximally proximal placement of the coil elements. By using small wire loops with the least number of solder joints, we were able to maximize the Q factor of the individual elements. Finally, by planning the placement of the coils using the brain atlas, we were able to target the arrangement of the coil elements to the extent of the visual cortex. Results: The combined optimizations led to as much as two‐fold SNR gain compared with a whole‐head 32‐channel coil. This gain was reflected in temporal SNR as well and enabled fMRI mapping at 0.75 mm resolutions using a conventional GRAPPA‐accelerated gradient echo echo planar imaging. Conclusion: Integrated optimization of shape, electronics, and element placement can lead to large gains in SNR and empower submillimeter fMRI at 3T. Magn Reson Med 76:321–328, 2016. © 2015 Wiley Periodicals, Inc.

Description

Keywords

Full Paper, magnetic resonance imaging, phased‐array, fMRI, parallel imaging, shape optimization, ocular dominance columns, functional MRI, orientation columns, accelerated EPI

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service