Publication:

Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in Humans

Loading...
Thumbnail Image

Date

2016

Published Version

Journal Title

Journal ISSN

Volume Title

Publisher

John Wiley and Sons Inc.
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Shishido, K., A. P. Antoniadis, S. Takahashi, M. Tsuda, S. Mizuno, I. Andreou, M. I. Papafaklis, et al. 2016. “Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in Humans.” Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease 5 (9): e002949. doi:10.1161/JAHA.115.002949. http://dx.doi.org/10.1161/JAHA.115.002949.

Abstract

Background: In‐stent hyperplasia (ISH) may develop in regions of low endothelial shear stress (ESS), but the relationship between the magnitude of low ESS, the extent of ISH, and subsequent clinical events has not been investigated. Methods and Results: We assessed the association of poststent ESS with neointimal ISH and clinical outcomes in patients treated with percutaneous coronary interventions (PCI). Three‐dimensional coronary reconstruction was performed in 374 post‐PCI patients at baseline and 6 to 10 months follow‐up as part of the PREDICTION Study. Each vessel was divided into 1.5‐mm‐long segments, and we calculated the local ESS within each stented segment at baseline. At follow‐up, we assessed ISH and the occurrence of a clinically indicated repeat PCI for in‐stent restenosis. In 246 total stents (54 overlapping), 100 (40.7%) were bare‐metal stents (BMS), 104 (42.3%) sirolimus‐eluting stents, and 42 (17.1%) paclitaxel‐eluting stents. In BMS, low ESS post‐PCI at baseline was independently associated with ISH (β=1.47 mm2 per 1‐Pa decrease; 95% CI, 0.38–2.56; P<0.01). ISH was minimal in drug‐eluting stents. During follow‐up, repeat PCI in BMS was performed in 21 stents (8.5%). There was no significant association between post‐PCI ESS and in‐stent restenosis requiring PCI. Conclusions: Low ESS after BMS implantation is associated with subsequent ISH. ISH is strongly inhibited by drug‐eluting stents. Post‐PCI ESS is not associated with in‐stent restenosis requiring repeat PCI. ESS is an important determinant of ISH in BMS, but ISH of large magnitude to require PCI for in‐stent restenosis is likely attributed to factors other than ESS within the stent.

Description

Research Data

Keywords

imaging, in‐stent restenosis, neointimal hyperplasia, percutaneous coronary intervention, shear stress, Vascular Biology

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories