Publication:

Imaging Analysis of the Hard X-ray Telescope ProtoEXIST2 and New Techniques for High Resolution Coded Aperture Telescopes

Loading...
Thumbnail Image

Date

2016

Journal Title

Journal ISSN

Volume Title

Publisher

American Astronomical Society
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Hong, Jaesub, Branden Allen, Jonathan Grindlay, and Scott Barthelmy. 2016. Imaging Analysis of the Hard X-ray Telescope ProtoEXIST2 and New Techniques for High Resolution Coded Aperture Telescopes. The Astronomical Journal 153 (1) (December 19): 11. doi:10.3847/1538-3881/153/1/11.

Abstract

Wide-field (& 100 deg2) hard X-ray coded-aperture telescopes with high angular resolution (. 20) will enable a wide range of time domain astrophysics. For instance, transient sources such as gammaray bursts can be precisely localized without assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a time scale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to high resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during the high-altitude balloon flight in Fall, 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with simulated ideal Poisson background.

Description

Other Available Sources

Research Data

Keywords

hard X-ray Imaging, CdZnTe, Coded-aperture imaging

Terms of Use

This article is made available under the terms and conditions applicable to Open Access Policy Articles (OAP), as set forth at Terms of Service