Publication: Patient satisfaction and wait times following outpatient manual vacuum aspiration compared to electric vacuum aspiration in the operating room: a cross-sectional study
Open/View Files
Date
2017
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
Springer Nature
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Dodge, Laura E., Lisa G. Hofler, Michele R. Hacker, and Sadia Haider. 2017. “Patient Satisfaction and Wait Times Following Outpatient Manual Vacuum Aspiration Compared to Electric Vacuum Aspiration in the Operating Room: a Cross-Sectional Study.” Contraception and Reproductive Medicine 2 (1) (June 7). doi:10.1186/s40834-017-0045-6.
Research Data
Abstract
Background
Outpatient manual vacuum aspiration (MVA) is a safe and equally effective alternative to electric vacuum aspiration (EVA) in the operating room. This project was conducted to determine whether outpatient MVA expedites care while maintaining patient satisfaction.
Methods
A cross-sectional study of a convenience sample of patients undergoing surgical management of spontaneous abortion, induced abortion, or retained products of conception with either outpatient MVA under local anesthesia or EVA in the operating room was conducted. Of 138 women completing surveys, 48 (34.8%) underwent outpatient MVA and 90 (65.2%) underwent EVA in the operating room. Procedure length, time from decision to procedure, and patient satisfaction were assessed through a self-administered questionnaire completed post-procedure.
Results
Most (77%) patients in the MVA group reported waiting fewer than 2 h from the time of their decision to the procedure, while most (74%) EVA patients reported waiting over 12 h (P < 0.001); the MVA group reported higher satisfaction with time to procedure (P = 0.02). The median procedure length was significantly shorter in the EVA group (10 vs. 20 min, P < 0.001). There was no significant difference between groups in overall satisfaction with the procedure (P = 0.16).
Conclusion
Outpatient MVA under local anesthesia is a suitable alternative to operating room-based EVA for management of spontaneous abortion, induced abortion, and retained products of conception. Outpatient MVA is associated with shorter decision-to-procedure time and is highly acceptable to patients. Integration of outpatient MVA into clinical settings can add time- and resource-saving options for uterine evacuation while maintaining a positive patient experience.
Description
Other Available Sources
Keywords
manual vacuum aspiration, Electric vacuum aspiration, Uterine evacuation, Patient acceptability
Terms of Use
This article is made available under the terms and conditions applicable to Open Access Policy Articles (OAP), as set forth at Terms of Service