DASH
Repository logo
Communities & Collections
Browse DASH
DASH Stories
Statistics
  1. Home
  2. Harvard Medical School
  3. HMS Scholarly Articles
  4. Dynamic 31P–MRSI using spiral spectroscopic imaging can map mitochondrial capacity in muscles of the human calf during plantar flexion exercise at 7 T

Dynamic 31P–MRSI using spiral spectroscopic imaging can map mitochondrial capacity in muscles of the human calf during plantar flexion exercise at 7 T

Open/View files
5132121.pdf (1.56 MB)
Date
2016
Author(s)
Valkovič, Ladislav
Chmelík, Marek
Meyerspeer, Martin
Gagoski, Borjan
Rodgers, Christopher T.
Krššák, Martin
Trattnig, Siegfried
Bogner, Wolfgang
DOI
10.1002/nbm.3662
Publisher
John Wiley and Sons Inc.
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Valkovič, Ladislav, Marek Chmelík, Martin Meyerspeer, Borjan Gagoski, Christopher T. Rodgers, Martin Krššák, Ovidiu C. Andronesi, Siegfried Trattnig, and Wolfgang Bogner. 2016. “Dynamic 31P–MRSI using spiral spectroscopic imaging can map mitochondrial capacity in muscles of the human calf during plantar flexion exercise at 7 T.” Nmr in Biomedicine 29 (12): 1825-1834. doi:10.1002/nbm.3662. http://dx.doi.org/10.1002/nbm.3662.
Abstract
Abstract Phosphorus MRSI (31P–MRSI) using a spiral‐trajectory readout at 7 T was developed for high temporal resolution mapping of the mitochondrial capacity of exercising human skeletal muscle. The sensitivity and localization accuracy of the method was investigated in phantoms. In vivo performance was assessed in 12 volunteers, who performed a plantar flexion exercise inside a whole‐body 7 T MR scanner using an MR‐compatible ergometer and a surface coil. In five volunteers the knee was flexed (~60°) to shift the major workload from the gastrocnemii to the soleus muscle. Spiral‐encoded MRSI provided 16–25 times faster mapping with a better point spread function than elliptical phase‐encoded MRSI with the same matrix size. The inevitable trade‐off for the increased temporal resolution was a reduced signal‐to‐noise ratio, but this was acceptable. The phosphocreatine (PCr) depletion caused by exercise at 0° knee angulation was significantly higher in both gastrocnemii than in the soleus (i.e. 64.8 ± 19.6% and 65.9 ± 23.6% in gastrocnemius lateralis and medialis versus 15.3 ± 8.4% in the soleus). Spiral‐encoded 31P–MRSI is a powerful tool for dynamic mapping of exercising muscle oxidative metabolism, including localized assessment of PCr concentrations, pH and maximal oxidative flux with high temporal and spatial resolution.
Other Available Sources
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5132121/pdf/
Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service
URI
http://nrs.harvard.edu/urn-3:HUL.InstRepos:29739095
Subjects

dynamic

high energy phosphate...

MRSI

skeletal muscle

spiral spectroscopic ...

ultra‐high field

Collection
HMS Scholarly Articles
Metrics
Repository logo
  • CONTACT US
  • OSRDS
  • ABOUT DASH
  • DEPOSITING TO DASH
  • TERMS OF USE
  • REQUEST A WAIVER
  • TAKE DOWN POLICY
  • NAME CHANGE POLICY
  • HARVARD OA POLICIES
  • DASH SUBMITTER AGREEMENT
  • Accessibility
  • Privacy
Creative Commons License BY
Creative Commons Attribution 4.0 International License

Except where otherwise noted, this work is subject to a Creative Commons Attribution 4.0 International License,
which allows anyone to share and adapt our material as long as proper attribution is given.
For details and exceptions, see the Harvard Library Copyright Policy
©2024 Presidents and Fellows of Harvard College.