Publication:
Evaluation of pulse oximeter derived photoplethysmographic signals for obstructive sleep apnea diagnosis

Thumbnail Image

Date

2017

Journal Title

Journal ISSN

Volume Title

Publisher

Wolters Kluwer Health
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Li, Yan, He Gao, and Yan Ma. 2017. “Evaluation of pulse oximeter derived photoplethysmographic signals for obstructive sleep apnea diagnosis.” Medicine 96 (18): e6755. doi:10.1097/MD.0000000000006755. http://dx.doi.org/10.1097/MD.0000000000006755.

Research Data

Abstract

Abstract High prevalence of obstructive sleep apnea (OSA) has increased the demands for more convenient and accessible diagnostic devices other than standard in-lab polysomnography (PSG). Despite the increasing utility of photoplethysmograph (PPG), it remains understudied in underserved populations. This study aimed to evaluate the reliability of a standard pulse oximeter system with an automated analysis based on the PPG signal for the diagnosis of OSA, as compared with PSG derived measures. Consecutive out-patients with suspect OSA completed a PPG monitoring simultaneous with an overnight in-lab standard PSG. Forty-nine OSA patients (38 males, age 43.5 ± 16.9 years, BMI 26.9 ± 0.5 kg/m2) were included in this study. Automated analyses were based on PPG and oximetry signals only. The PPG calculated measures were compared with PSG derived measures for agreement tests. Respiratory events index derived from PPG significantly correlated with PSG-derived apnea–hypopnea index (r = 0.935, P < .001). The calculation of total sleep time and oxygen desaturation index from PPG and PSG also significantly correlated (r = 0.418, P = .003; r = 0.933, P < .001, respectively). Bland–Altman plots showed good agreement between the PPG and the PSG measures. The overall sensitivity and specificity of PPG are good, especially in moderate and severe OSA groups. The tested PPG approach yielded acceptable results compared to the gold standard PSG among moderate to severe OSA patients. A pulse oximeter system with PPG recording can be used for the diagnosis or screening of OSA in high risk population.

Description

Keywords

Observational Study, agreement, obstructive sleep apnea, photoplethysmography, polysomnography, portable monitors, pulse oximeter, sleep

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Referenced By

Related Stories