Publication:

Safety and Efficacy of Rivaroxaban in Patients With Cardiac Implantable Electronic Devices: Observations From the ROCKET AF Trial

Loading...
Thumbnail Image

Date

2017

Published Version

Journal Title

Journal ISSN

Volume Title

Publisher

John Wiley and Sons Inc.
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Leef, G. C., A. S. Hellkamp, M. R. Patel, R. C. Becker, S. D. Berkowitz, G. Breithardt, J. L. Halperin, et al. 2017. “Safety and Efficacy of Rivaroxaban in Patients With Cardiac Implantable Electronic Devices: Observations From the ROCKET AF Trial.” Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease 6 (6): e004663. doi:10.1161/JAHA.116.004663. http://dx.doi.org/10.1161/JAHA.116.004663.

Abstract

Background: Although implantation of cardiac implantable electronic devices (CIEDs) in patients receiving warfarin is well studied, limited data are available on the use of oral factor Xa inhibitors in this setting. Methods and Results: Using data from Rivaroxaban Once Daily Oral Direct Factor Xa Inhibition Compared with Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation (ROCKET AF) (n=14 264), we compared baseline characteristics and clinical outcomes in patients with atrial fibrillation randomized to rivaroxaban versus warfarin who did and did not undergo CIED implantation or revision. In this post‐hoc, postrandomization, on‐treatment analysis, only the first intervention per patient was analyzed. During a median follow‐up of 2.2 years, 453 patients (242 rivaroxaban group; 211 warfarin group) underwent de novo CIED implantation (64.2%) or revision procedures (35.8%). Patients who received CIEDs were older, more likely to be male, and more likely to have past myocardial infarction, but had similar stroke risk compared to patients who did not receive CIEDs. Most patients who received a device had study drug interrupted for the procedure and did not receive bridging anticoagulation. During the 30‐day postprocedural period, 11 patients (4.55%) in the rivaroxaban group experienced bleeding complications compared with 15 (7.13%) in the warfarin group. Thromboembolic complications occurred in 3 patients (1.26%) in the rivaroxaban group and 1 (0.48%) in the warfarin group. Event rates were too low for formal hypothesis testing. Conclusions: Bleeding and thromboembolic events were low in both rivaroxaban‐ and warfarin‐treated patients. Periprocedural use of oral factor Xa inhibitors in CIED implantation requires further study in prospective, randomized trials. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT00403767.

Description

Research Data

Keywords

anticoagulation, atrial fibrillation, cardiac resynchronization therapy, factor Xa inhibitor, implantable cardioverter‐defibrillator, pacemaker, rivaroxaban, warfarin, Catheter Ablation and Implantable Cardioverter-Defibrillator, Anticoagulants, Pacemaker, Electrophysiology