Publication: Using needle orientation sensing as surrogate signal for respiratory motion estimation in percutaneous interventions
Open/View Files
Date
2017
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
Springer International Publishing
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Abayazid, Momen, Takahisa Kato, Stuart G. Silverman, and Nobuhiko Hata. 2017. “Using needle orientation sensing as surrogate signal for respiratory motion estimation in percutaneous interventions.” International Journal of Computer Assisted Radiology and Surgery 13 (1): 125-133. doi:10.1007/s11548-017-1644-z. http://dx.doi.org/10.1007/s11548-017-1644-z.
Research Data
Abstract
Purpose To develop and evaluate an approach to estimate the respiratory-induced motion of lesions in the chest and abdomen. Materials and methods The proposed approach uses the motion of an initial reference needle inserted into a moving organ to estimate the lesion (target) displacement that is caused by respiration. The needles position is measured using an inertial measurement unit (IMU) sensor externally attached to the hub of an initially placed reference needle. Data obtained from the IMU sensor and the target motion are used to train a learning-based approach to estimate the position of the moving target. An experimental platform was designed to mimic respiratory motion of the liver. Liver motion profiles of human subjects provided inputs to the experimental platform. Variables including the insertion angle, target depth, target motion velocity and target proximity to the reference needle were evaluated by measuring the error of the estimated target position and processing time. Results: The mean error of estimation of the target position ranged between 0.86 and 1.29 mm. The processing maximum training and testing time was 5 ms which is suitable for real-time target motion estimation using the needle position sensor. Conclusion: The external motion of an initially placed reference needle inserted into a moving organ can be used as a surrogate, measurable and accessible signal to estimate in real-time the position of a moving target caused by respiration; this technique could then be used to guide the placement of subsequently inserted needles directly into the target.
Description
Other Available Sources
Keywords
Machine learning, Motion compensation, Respiratory motion, Magnetic resonance imaging, Percutaneous needle insertion, Interventional radiology
Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service