Tshikudi, Diane M., Markandey M. Tripathi, Zeinab Hajjarian, Elizabeth M. Van Cott, and Seemantini K. Nadkarni. 2017. “Optical sensing of anticoagulation status: Towards point-of-care coagulation testing.” PLoS ONE 12 (8): e0182491. doi:10.1371/journal.pone.0182491. http://dx.doi.org/10.1371/journal.pone.0182491.

Abstract

Anticoagulant overdose is associated with major bleeding complications. Rapid coagulation sensing may ensure safe and accurate anticoagulant dosing and reduce bleeding risk. Here, we report the novel use of Laser Speckle Rheology (LSR) for measuring anticoagulation and haemodilution status in whole blood. In the LSR approach, blood from 12 patients and 4 swine was placed in disposable cartridges and time-varying intensity fluctuations of laser speckle patterns were measured to quantify the viscoelastic modulus during clotting. Coagulation parameters, mainly clotting time, clot progression rate (α-angle) and maximum clot stiffness (MA) were derived from the clot viscoelasticity trace and compared with standard Thromboelastography (TEG). To demonstrate the capability for anticoagulation sensing in patients, blood samples from 12 patients treated with warfarin anticoagulant were analyzed. LSR clotting time correlated with prothrombin and activated partial thromboplastin time (r = 0.57–0.77, p<0.04) and all LSR parameters demonstrated good correlation with TEG (r = 0.61–0.87, p<0.04). To further evaluate the dose-dependent sensitivity of LSR parameters, swine blood was spiked with varying concentrations of heparin, argatroban and rivaroxaban or serially diluted with saline. We observed that anticoagulant treatments prolonged LSR clotting time in a dose-dependent manner that correlated closely with TEG (r = 0.99, p<0.01). LSR angle was unaltered by anticoagulation whereas TEG angle presented dose-dependent diminution likely linked to the mechanical manipulation of the clot. In both LSR and TEG, MA was largely unaffected by anticoagulation, and LSR presented a higher sensitivity to increased haemodilution in comparison to TEG (p<0.01). Our results establish that LSR rapidly and accurately measures the response of various anticoagulants, opening the opportunity for routine anticoagulation monitoring at the point-of-care or for patient self-testing.

Description

Research Data

Keywords

Biology and Life Sciences, Anatomy, Body Fluids, Blood, Medicine and Health Sciences, Physiology, Pharmacology, Drugs, Heparin, Organisms, Animals, Vertebrates, Amniotes, Mammals, Swine, Anticoagulants, Biochemistry, Proteins, Thrombin, Engineering and Technology, Equipment, Optical Equipment, Lasers, Diagnostic Medicine, Signs and Symptoms, Hemorrhage, Pathology and Laboratory Medicine, Vascular Medicine, Fibrin

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories