Publication:
Maternal blood contamination of collected cord blood can be identified using DNA methylation at three CpGs

Thumbnail Image

Open/View Files

Date

2017

Journal Title

Journal ISSN

Volume Title

Publisher

BioMed Central
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Morin, A. M., E. Gatev, L. M. McEwen, J. L. MacIsaac, D. T. S. Lin, N. Koen, D. Czamara, et al. 2017. “Maternal blood contamination of collected cord blood can be identified using DNA methylation at three CpGs.” Clinical Epigenetics 9 (1): 75. doi:10.1186/s13148-017-0370-2. http://dx.doi.org/10.1186/s13148-017-0370-2.

Research Data

Abstract

Background: Cord blood is a commonly used tissue in environmental, genetic, and epigenetic population studies due to its ready availability and potential to inform on a sensitive period of human development. However, the introduction of maternal blood during labor or cross-contamination during sample collection may complicate downstream analyses. After discovering maternal contamination of cord blood in a cohort study of 150 neonates using Illumina 450K DNA methylation (DNAm) data, we used a combination of linear regression and random forest machine learning to create a DNAm-based screening method. We identified a panel of DNAm sites that could discriminate between contaminated and non-contaminated samples, then designed pyrosequencing assays to pre-screen DNA prior to being assayed on an array. Results: Maternal contamination of cord blood was initially identified by unusual X chromosome DNA methylation patterns in 17 males. We utilized our DNAm panel to detect contaminated male samples and a proportional amount of female samples in the same cohort. We validated our DNAm screening method on an additional 189 sample cohort using both pyrosequencing and DNAm arrays, as well as 9 publically available cord blood 450K data sets. The rate of contamination varied from 0 to 10% within these studies, likely related to collection specific methods. Conclusions: Maternal blood can contaminate cord blood during sample collection at appreciable levels across multiple studies. We have identified a panel of markers that can be used to identify this contamination, either post hoc after DNAm arrays have been completed, or in advance using a targeted technique like pyrosequencing. Electronic supplementary material The online version of this article (doi:10.1186/s13148-017-0370-2) contains supplementary material, which is available to authorized users.

Description

Keywords

Cord blood, Contamination, DNA methylation, 450K, Genotyping, Maternal blood, Blood banking

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Referenced By

Related Stories