Publication:
Rapid histopathological imaging of skin and breast cancer surgical specimens using immersion microscopy with ultraviolet surface excitation

Thumbnail Image

Open/View Files

Date

2018

Journal Title

Journal ISSN

Volume Title

Publisher

Nature Publishing Group UK
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Yoshitake, Tadayuki, Michael G. Giacomelli, Liza M. Quintana, Hilde Vardeh, Lucas C. Cahill, Beverly E. Faulkner-Jones, James L. Connolly, Daihung Do, and James G. Fujimoto. 2018. “Rapid histopathological imaging of skin and breast cancer surgical specimens using immersion microscopy with ultraviolet surface excitation.” Scientific Reports 8 (1): 4476. doi:10.1038/s41598-018-22264-2. http://dx.doi.org/10.1038/s41598-018-22264-2.

Research Data

Abstract

Rapid histopathological evaluation of fresh, unfixed human tissue using optical sectioning microscopy would have applications to intraoperative surgical margin assessment. Microscopy with ultraviolet surface excitation (MUSE) is a low-cost optical sectioning technique using ultraviolet illumination which limits fluorescence excitation to the specimen surface. In this paper, we characterize MUSE using high incident angle, water immersion illumination to improve sectioning. Propidium iodide is used as a nuclear stain and eosin yellow as a counterstain. Histologic features of specimens using MUSE, nonlinear microscopy (NLM) and conventional hematoxylin and eosin (H&E) histology were evaluated by pathologists to assess potential application in Mohs surgery for skin cancer and lumpectomy for breast cancer. MUSE images of basal cell carcinoma showed high correspondence with frozen section H&E histology, suggesting that MUSE may be applicable to Mohs surgery. However, correspondence in breast tissue between MUSE and paraffin embedded H&E histology was limited due to the thicker optical sectioning in MUSE, suggesting that further development is needed for breast surgical applications. We further demonstrate that the transverse image resolution of MUSE is limited by the optical sectioning thickness and use co-registered NLM to quantify the improvement in MUSE optical sectioning from high incident angle water immersion illumination.

Description

Keywords

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Referenced By

Related Stories