Publication:
Deficits in functional performance and gait one year after total knee arthroplasty despite improved self-reported function

Thumbnail Image

Date

2016

Journal Title

Journal ISSN

Volume Title

Publisher

Springer Berlin Heidelberg
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Naili, Josefine E., Maura D. Iversen, Anna-Clara Esbjörnsson, Margareta Hedström, Michael H. Schwartz, Charlotte K. Häger, and Eva W. Broström. 2016. “Deficits in functional performance and gait one year after total knee arthroplasty despite improved self-reported function.” Knee Surgery, Sports Traumatology, Arthroscopy 25 (11): 3378-3386. doi:10.1007/s00167-016-4234-7. http://dx.doi.org/10.1007/s00167-016-4234-7.

Research Data

Abstract

Purpose The current literature lacks sufficient information about improvements in gait patterns and function after total knee arthroplasty (TKA) and whether patients return to full function. This study evaluated change in gait, performance-based function, and self-reported function 1 year after TKA in patients with symptomatic knee osteoarthritis and how these aspects interrelate. Methods: A total of 28 patients (64 % female) with knee osteoarthritis, with a mean age of 66 (±7) years, and 25 age- and gender-matched controls participated in this prospective cohort study. Three-dimensional gait analysis generated comprehensive measures of kinematic and kinetic gait deviations, respectively. Participants completed the Five Times Sit-to-Stand (5STS) test, and the self-reported questionnaire Knee Injury and Osteoarthritis Outcome Score (KOOS), at baseline prior to surgery and 1 year after TKA. Results: Kinetic gait deviations of both the operated and non-operated limb persisted in patients with knee osteoarthritis at 1 year after surgery, while kinematic gait patterns were comparable to controls. Performance on the 5STS and KOOS scores in patients with knee osteoarthritis improved significantly 1 year after surgery (effect size 0.5–1.5), but did not reach the level of controls. Ten patients with knee osteoarthritis (36 %) exceeded the minimally detectable change on the 5STS. Conclusion: Measures of overall gait patterns and the 5STS revealed improvements in function 1 year after TKA, but were not restored to the level of healthy controls. Based on change in 5STS performance, we identified patients with substantial improvements in gait patterns. Self-reported measures of function could not detect differences between patients improving in 5STS performance and those who did not. These findings highlight the use of the 5STS in clinical practice since improvement on this test seems to follow the reduction in gait pattern deviations. Level of evidence II.

Description

Keywords

Arthroplasty, Knee osteoarthritis, Outcome, Gait, Function, Biomechanics, Patient-reported outcome, Mobile bearing

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Referenced By

Related Stories