Publication:

Nuclear IHC enumeration: A digital phantom to evaluate the performance of automated algorithms in digital pathology

Loading...
Thumbnail Image

Open/View Files

Date

2018

Journal Title

Journal ISSN

Volume Title

Publisher

Public Library of Science
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Niazi, M. K. K., F. S. Abas, C. Senaras, M. Pennell, B. Sahiner, W. Chen, J. Opfer, et al. 2018. “Nuclear IHC enumeration: A digital phantom to evaluate the performance of automated algorithms in digital pathology.” PLoS ONE 13 (5): e0196547. doi:10.1371/journal.pone.0196547. http://dx.doi.org/10.1371/journal.pone.0196547.

Abstract

Automatic and accurate detection of positive and negative nuclei from images of immunostained tissue biopsies is critical to the success of digital pathology. The evaluation of most nuclei detection algorithms relies on manually generated ground truth prepared by pathologists, which is unfortunately time-consuming and suffers from inter-pathologist variability. In this work, we developed a digital immunohistochemistry (IHC) phantom that can be used for evaluating computer algorithms for enumeration of IHC positive cells. Our phantom development consists of two main steps, 1) extraction of the individual as well as nuclei clumps of both positive and negative nuclei from real WSI images, and 2) systematic placement of the extracted nuclei clumps on an image canvas. The resulting images are visually similar to the original tissue images. We created a set of 42 images with different concentrations of positive and negative nuclei. These images were evaluated by four board certified pathologists in the task of estimating the ratio of positive to total number of nuclei. The resulting concordance correlation coefficients (CCC) between the pathologist and the true ratio range from 0.86 to 0.95 (point estimates). The same ratio was also computed by an automated computer algorithm, which yielded a CCC value of 0.99. Reading the phantom data with known ground truth, the human readers show substantial variability and lower average performance than the computer algorithm in terms of CCC. This shows the limitation of using a human reader panel to establish a reference standard for the evaluation of computer algorithms, thereby highlighting the usefulness of the phantom developed in this work. Using our phantom images, we further developed a function that can approximate the true ratio from the area of the positive and negative nuclei, hence avoiding the need to detect individual nuclei. The predicted ratios of 10 held-out images using the function (trained on 32 images) are within ±2.68% of the true ratio. Moreover, we also report the evaluation of a computerized image analysis method on the synthetic tissue dataset.

Description

Research Data

Keywords

People and Places, Population Groupings, Professions, Medical Personnel, Medical Doctors, Pathologists, Medicine and Health Sciences, Health Care, Health Care Providers, Physical Sciences, Mathematics, Applied Mathematics, Algorithms, Simulation and Modeling, Specimen Preparation and Treatment, Staining, Cell Staining, Computer and Information Sciences, Computers, Imaging Techniques, Histochemistry and Cytochemistry Techniques, Immunohistochemistry Techniques, Immunologic Techniques, Oncology, Cancers and Neoplasms, Malignant Tumors, Negative Staining

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories