Publication:
Safety of a condom uterine balloon tamponade (ESM-UBT) device for uncontrolled primary postpartum hemorrhage among facilities in Kenya and Sierra Leone

Thumbnail Image

Date

2018

Journal Title

Journal ISSN

Volume Title

Publisher

BioMed Central
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Ramanathan, Aparna, Melody J. Eckardt, Brett D. Nelson, Moytrayee Guha, Monica Oguttu, Zaid Altawil, and Thomas Burke. 2018. “Safety of a condom uterine balloon tamponade (ESM-UBT) device for uncontrolled primary postpartum hemorrhage among facilities in Kenya and Sierra Leone.” BMC Pregnancy and Childbirth 18 (1): 168. doi:10.1186/s12884-018-1808-z. http://dx.doi.org/10.1186/s12884-018-1808-z.

Research Data

Abstract

Background: Postpartum hemorrhage is the leading cause of maternal mortality in low- and middle-income countries. While evidence on uterine balloon tamponade efficacy for severe hemorrhage is encouraging, little is known about safety of this intervention. The objective of this study was to evaluate the safety of an ultra-low-cost uterine balloon tamponade package (named ESM-UBT) for facility-based management of uncontrolled postpartum hemorrhage (PPH) in Kenya and Sierra Leone. Methods: Data were collected on complications/adverse events in all women who had an ESM-UBT device placed among 92 facilities in Sierra Leone and Kenya, between September 2012 and December 2015, as part of a multi-country study. Three expert maternal health investigator physicians analyzed each complication/adverse event and developed consensus on whether there was a potential causal relationship associated with use of the ESM-UBT device. Adverse events/complications specifically investigated included death, hysterectomy, uterine rupture, perineal or cervical injury, serious or minor infection, and latex allergy/anaphylaxis. Results: Of the 201 women treated with an ESM-UBT device in Kenya and Sierra Leone, 189 (94.0%) survived. Six-week or longer follow-up was recorded in 156 of the 189 (82.5%). A causal relationship between use of an ESM-UBT device and one death, three perineal injuries and one case of mild endometritis could not be completely excluded. Three experts found a potential association between these injuries and an ESM-UBT device highly unlikely. Conclusion: The ESM-UBT device appears safe for use in women with uncontrolled PPH. Trial registration Trial registration was not completed as data was collected as a quality assurance measure for the ESM-UBT kit.

Description

Keywords

Uterine balloon tamponade, Postpartum hemorrhage, Maternal mortality, Maternal health, Developing countries

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Referenced By

Related Stories