Publication:
Exhaled Nitric Oxide as a Diagnostic Test for Asthma: Online Versus Offline Techniques and Effect of Flow Rate

No Thumbnail Available

Date

2002-03-19

Published Version

Journal Title

Journal ISSN

Volume Title

Publisher

American Thoracic Society
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Deykin, Aaron, Anthony F. Massaro, Jeffrey M. Drazen, and Elliot Israel. 2002. Exhaled Nitric Oxide as a Diagnostic Test for Asthma: Online versus Offline Techniques and Effect of Flow Rate. American Journal of Respiratory and Critical Care Medicine 165, no. 12: 1597-601.

Research Data

Abstract

Measurement of the fraction of exhaled nitric oxide (FeNO) has been proposed as a noninvasive assessment of asthmatic airway inflammation. The influence of the expiratory flow rate during the collection maneuver on the ability of FeNO to discriminate healthy subjects from those with asthma is unknown. We compared online and offline measurement of FeNO at different flow rates. FeNO was collected with expiratory flows of 50–500 ml/second in 34 patients with asthma (PC20 of less than 8 mg/ml) and 28 healthy subjects (PC20 of more than 10 mg/ml) using offline collection techniques. In a subgroup of 18 individuals with asthma and 17 healthy subjects, we additionally measured FeNO at multiple expiratory flow rates (47–250 ml/second) using online methods. FeNO fell with an increasing expiratory flow rate; FeNO was higher in subjects with asthma as compared with healthy subjects at each flow rate studied with both techniques (p < 0.001). Receiver operating characteristic (ROC) curves for the diagnosis of asthma indicated that FeNO is a robust discriminator between individuals with asthma and healthy subjects (area under the ROC curves 0.79 ± 0.06 to 0.86 ± 0.06, p for significant discrimination < 0.0001). Neither expiratory flow rate nor collection technique (online versus offline) significantly altered this discriminatory capacity (area under the ROC curves = 0.84 ± 0.07 with the slowest online method versus 0.80 ± 0.07 with the fastest offline method, p = 0.46). These data indicate that the choice of expiratory flow rate and collection method can be based on practicality and patient comfort without compromising the utility of this test for asthma.

Description

Other Available Sources

Keywords

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Referenced By

Related Stories