Publication: Lumpectomy Specimen Radiography: Does Orientation or 3D Tomosynthesis Improve Margin Assessment?
Open/View Files
Date
2019-03-27
Authors
Published Version
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Mario, Julia. 2017. Lumpectomy Specimen Radiography: Does Orientation or 3D Tomosynthesis Improve Margin Assessment?. Doctoral dissertation, Harvard Medical School.
Research Data
Abstract
Objective: To determine 1) whether 2 orthogonal oriented 2D views of excised breast cancer specimens improves surgical margin (SM) assessment compared to a single unoriented 2D view and 2) whether 2 orthogonal oriented views using 3D tomosynthesis improves SM assessment compared to 2 orthogonal oriented 2D views.
Methods: 41 specimens were imaged using four protocols: single view unoriented 2D image acquired on a specimen unit (1VSU), two orthogonal oriented 2D images acquired on the specimen unit (2VSU), two orthogonal oriented 2D images acquired on a mammogram unit (2V2DMU), and two orthogonal oriented 3D images acquired on the mammogram unit (2V3DMU). Three breast imagers retrospectively and randomly assessed SM of the 41 specimens with each protocol. SM per histopathology was considered the gold standard.
Results: The average area under the curve (AUC) was 0.60 for 1VSU, 0.66 for 2VSU, 0.68 for 2V2DMU, and 0.60 for 2V3DMU. Comparing AUCs for 2VSU vs. 1VSU by reader showed improved diagnostic accuracy using 2VSU, however this difference was only statistically significant for reader 3 (0.73 vs. 0.63, p = 0.0455). Comparing AUCs for 2V3DMU vs. 2V2DMU by reader showed mixed results, with reader 1 demonstrating increased accuracy (0.72 vs. 0.68, p = 0.5984) while readers 2 and 3 demonstrated decreased accuracy (0.50 vs. 0.62, p = 0.1089 and 0.58 vs. 0.75, p = 0.0269).
Conclusions: 2VSU showed improved accuracy in SM prediction compared to 1VSU, although this was not statistically significant for all readers. 3D tomosynthesis did not improve SM assessment.
Description
Other Available Sources
Keywords
breast cancer specimen, digital breast tomosynthesis, orthogonal views, surgical margins, lumpectomy specimen radiography
Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service