Person:

Rodriguez, Edward

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Rodriguez

First Name

Edward

Name

Rodriguez, Edward

Search Results

Now showing 1 - 4 of 4
  • Publication

    Bone fracture healing in mechanobiological modeling: A review of principles and methods

    (Elsevier, 2017) Ghiasi, Mohammad S.; Chen, Jason; Vaziri, Ashkan; Rodriguez, Edward; Nazarian, Ara

    Bone fracture is a very common body injury. The healing process is physiologically complex, involving both biological and mechanical aspects. Following a fracture, cell migration, cell/tissue differentiation, tissue synthesis, and cytokine and growth factor release occur, regulated by the mechanical environment. Over the past decade, bone healing simulation and modeling has been employed to understand its details and mechanisms, to investigate specific clinical questions, and to design healing strategies. The goal of this effort is to review the history and the most recent work in bone healing simulations with an emphasis on both biological and mechanical properties. Therefore, we provide a brief review of the biology of bone fracture repair, followed by an outline of the key growth factors and mechanical factors influencing it. We then compare different methodologies of bone healing simulation, including conceptual modeling (qualitative modeling of bone healing to understand the general mechanisms), biological modeling (considering only the biological factors and processes), and mechanobiological modeling (considering both biological aspects and mechanical environment). Finally we evaluate different components and clinical applications of bone healing simulation such as mechanical stimuli, phases of bone healing, and angiogenesis.

  • Publication

    Lateral Femoral Traction Pin Entry: Risk to the Femoral Artery and Other Medial Neurovascular Structures

    (BioMed Central, 2010) Kwon, John; Johnson, Catherine E; Appleton, Paul; Rodriguez, Edward

    Background: Femoral skeletal traction assists in the reduction and transient stabilization of pelvic, acetabular, hip, and femoral fractures when splinting is ineffective. Traditional teaching has recommended a medial entry site for insertion of the traction pin in order to minimize injury to the femoral artery as it passes through Hunter's canal. The present anatomical study evaluates the risk to the femoral artery and other medial neurovascular structures using a lateral entry approach. Methods: Six embalmed cadavers (twelve femurs) were obtained for dissection. Steinman pins were drilled from lateral to medial at the level of the superior pole of the patella, at 2 cm, and at 4 cm proximal to this point. Medial superficial dissection was then performed to identify the saphenous nerve, the superior medial geniculate artery, the adductor hiatus, the tendinous insertion of the adductor magnus and the femoral artery. Measurements localizing these anatomic structures relative to the pins were obtained. Results: The femoral artery was relatively safe and was no closer than 29.6 mm (mean) from any of the three Steinman pins. The superior medial geniculate artery was the medial structure at most risk.Conclusions Lateral femoral traction pin entry is a safe procedure with minimal risk to the saphenous nerve and femoral artery. Of the structures examined, only the superior medial geniculate artery is at a risk of iatrogenic injury due to its position. The incidence of such injury in clinical practice and its clinical significance is not known. Lateral insertion facilitates traction pin placement since it minimizes the need to move the contralateral extremity out of the way of the drilling equipment or the need to elevate or externally rotate the injured extremity relative to the contralateral extremity.

  • Publication

    Recurrent Septic Arthritis Due to Achromobacter xylosoxidans in a Patient With Granulomatosis With Polyangiitis

    (Oxford University Press, 2015) Patel, Payal K.; Von Keudell, Arvind; Moroder, Philipp; Appleton, Paul; Wigmore, Robin; Rodriguez, Edward

    We report a case of recurrent Achromobacter xylosoxidans infections including bacteremia, sepsis, septic joints and endocarditis in a 72 year old female with granulomatosis with polyangiitis. Achromobacter xylosoxidans is a gram negative bacteria increasingly identified in immunocompromised patients. Surgical and medical therapy may need to be combined.

  • Publication

    The efficacy of a lysine-based dendritic hydrogel does not differ from those of commercially available tissue sealants and adhesives: an ex vivo study

    (BioMed Central, 2015) Villa-Camacho, Juan C; Ghobril, Cynthia; Anez-Bustillos, Lorenzo; Grinstaff, Mark W; Rodriguez, Edward; Nazarian, Ara

    Background: Hemostatic agents, tissue adhesives and sealants may contribute to a reduction in hemorrhage-associated morbidity and mortality. Towards this end, we have recently developed a lysine-based dendritic hydrogel (PEG-LysNH2) that can potentially be used in the management of severe trauma and/or intraoperative bleeding. As a first step in demonstrating the potential utility of this approach, our objective was to ascertain the ability of the PEG-LysNH2 to adhere to and seal injured tissues, as well as to maintain the seal under physiological conditions. Methods: The efficacy of the PEG-LysNH2 in sealing injured tissues was evaluated using an ex-vivo pressure testing system. A 2.5 mm incision was made on intact ex-vivo tissues and then sealed with the PEG-LysNH2. Application of the PEG-LysNH2 was followed by 1) step-wise pressure increase to a maximum of 250 mmHg and 2) fluctuating pressures, between 100–180 mmHg with a rate of 3 Hz, over a 24-hour period. The performance of the PEG-LysNH2 was compared to those of commercially available sealants and adhesives. Results: During gradual pressure increase, mean pressures at 30 seconds (P30) ranged between 206.36 - 220.17 mmHg for the sealants, and they were greater than control and suture groups (p < 0.01 and p = 0.013, respectively). Additionally, all products held under fluctuating pressures: mean pressures ranged between 135.20 - 160.09 mmHg, and there were no differences observed between groups (p = 0.96). Conclusions: The efficacy of the PEG-LysNH2 was significantly superior to conventional injury repair methods (sutures) and did not differ from those of commercially available products when sealing small incisions.