Person: Thomas, Ajith
Email Address
AA Acceptance Date
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
First Name
Name
Search Results
Publication Middle Meningeal Artery Arising from the Basilar Artery
(Korean Society of Cerebrovascular Surgeons; Society of Korean Endovascular Neurosurgeons, 2014) Salem, Mohamed; Fusco, Matthew R.; Dolati, Parviz; Reddy, Arra S.; Gross, Bradley A.; Ogilvy, Christopher; Thomas, AjithVarious anomalies for the origin of the middle meningeal artery (MMA) have been described in the literature. However, origin of the MMA from the basilar trunk is an extremely rare variant. We report on a 54-year-old female who presented with frequent headaches; magnetic resonance imaging showed a right parietal meningioma. The abnormal origin of the middle meningeal artery from the basilar artery was diagnosed by angiography performed for preoperative embolization of the tumor. We report on the case with a review of the embryologic basis, possible explanations for this aberrant origin, and its clinical implications.
Publication An Unruptured Anterior Communicating Artery Aneurysm with Bilateral Infraoptic Anterior Cerebral Arteries. Case Report and Review of the Literature
(Korean Society of Cerebrovascular Surgeons; Society of Korean Endovascular Neurosurgeons, 2014) Chua, Michelle H.; Thomas, Ajith; Fusco, Matthew R.; Ogilvy, ChristopherVariations of the anterior cerebral artery-anterior communicating artery complex are commonly identified in aneurysm surgery. An infraoptic course of the anterior cerebral artery is exceedingly rare. Robison first described this anomaly from an anatomic dissection in 1959. A unilateral anomalous infraoptic anterior cerebral artery is more common than anomalies of bilateral infraoptic anterior cerebral arteries. We present the case of an unruptured aneurysm at the anterior communicating artery in a patient with bilateral infraoptic anterior cerebral arteries, identified by computed tomography angiography and verified during surgery. Implications for aneurysm formation and surgical treatment are discussed.
Publication Assured Safety Drill With Bi-Stable Bit Retraction Mechanism
(ASME, 2013-08-04) Loschak, Paul; Xiao, Kechao; Pei, Hao; Kesner, Samuel; Thomas, Ajith; Walsh, ConorA handheld, portable cranial drilling tool for safely creating holes in the skull without damaging brain tissue is presented. Such a device is essential for neurosurgeons and mid-level practitioners treating patients with traumatic brain injury. A typical procedure creates a small hole for inserting sensors to monitor intra-cranial pressure measurements and/or removing excess fluid. Drilling holes in emergency settings with existing tools is difficult and dangerous due to the risk of a drill bit unintentionally plunging into brain tissue. Cranial perforators, which counter-bore holes and automatically stop upon skull penetration, do exist but are limited to large diameter hole size and an operating room environment. The tool presented here is compatible with a large range of bit diameters and provides safe, reliable access. This is accomplished through a dynamic bi-stable linkage that supports drilling when force is applied against the skull but retracts upon penetration when the reaction force is diminished. Retraction is achieved when centrifugal forces from rotating masses overpower the axial forces, thus changing the state of the bi-stable mechanism. Initial testing on ex-vivo animal structures has demonstrated that the device can withdraw the drill bit in sufficient time to eliminate the risk of soft tissue damage. Ease of use and portability of the device will enable its use in unregulated environments such as hospital emergency rooms and emergency disaster relief areas.
Publication Intra-arterial Onyx Embolization of Vertebral Body Lesions
(Korean Society of Cerebrovascular Surgeons; Society of Korean Endovascular Neurosurgeons, 2013) Sedora-Roman, Neda I.; Gross, Bradley A.; Reddy, Arra Suresh; Ogilvy, Christopher; Thomas, AjithWhile Onyx embolization of cerebrospinal arteriovenous shunts is well-established, clinical researchers continue to broaden applications to other vascular lesions of the neuraxis. This report illustrates the application of Onyx (eV3, Plymouth, MN) embolization to vertebral body lesions, specifically, a vertebral hemangioma and renal cell carcinoma vertebral body metastatic lesion.
Publication Preoperative Embolization of Extra-axial Hypervascular Tumors with Onyx
(Korean Society of Cerebrovascular Surgeons; Society of Korean Endovascular Neurosurgeons, 2016) Fusco, Matthew R.; Salem, Mohamed M.; Gross, Bradley A.; Reddy, Arra S.; Ogilvy, Christopher; Kasper, Ekkehard; Thomas, AjithObjective: Preoperative endovascular embolization of intracranial tumors is performed to mitigate anticipated intraoperative blood loss. Although the usage of a wide array of embolic agents, particularly polyvinyl alcohol (PVA), has been described for a variety of tumors, literature detailing the efficacy, safety and complication rates for the usage of Onyx is relatively sparse. Materials and Methods We reviewed our single institutional experience with pre-surgical Onyx embolization of extra-axial tumors to evaluate its efficacy and safety and highlight nuances of individualized cases. Results: Five patients underwent pre-surgical Onyx embolization of large or giant extra-axial tumors within 24 hours of surgical resection. Four patients harbored falcine or convexity meningiomas (grade I in 2 patients, grade II in 1 patient and grade III in one patient), and one patient had a grade II hemangiopericytoma. Embolization proceeded uneventfully in all cases and there were no complications. Conclusion: This series augments the expanding literature confirming the safety and efficacy of Onyx in the preoperative embolization of extra-axial tumors, underscoring its advantage of being able to attain extensive devascularization via only one supplying pedicle.
Publication Application of Pipeline Embolization Device for Iatrogenic Pseudoaneurysms of the Extracranial Vertebral Artery: A Case Report and Systematic Review of the Literature
(Cureus, 2015) Dolati, Parviz; Eichberg, Daniel G; Thomas, Ajith; Ogilvy, ChristopherTraumatic pseudoaneurysms of the vertebral artery (VA) are uncommon vascular lesions and definitive management is often challenging. Between 0% and 8% of craniocervical fusions are complicated by VA injury. In these cases, preserving the vertebral artery while treating the pseudoaneurysm is the goal of any treatment option. We describe the second known case of a patient with and iatrogenic extracranial vertebral artery pseudoaneurysm treated effectively using the Pipeline Embolization Device (PED) (Ev3 Neurovascular, Irvine, CA). Although there have been only two cases reported, the use of flow-diverting stents appears to be efficacious for the treatment of non-actively bleeding traumatic pseudoaneurysms.
Publication Use of an Absorbable Synthetic Polymer Dural Substitute for Repair of Dural Defects: A Technical Note
(Cureus, 2018) Schmalz, Philip; Griessenauer, Christoph; Ogilvy, Christopher; Thomas, AjithRepair of the dura after cranial neurosurgery can present a technical challenge and, for certain neurosurgical procedures, is critical to prevent cerebrospinal fluid leak and associated wound complications. Multiple options exist for dural repair, including the patient’s own tissues, bovine collagen-derived commercially available grafts, as well as newer, entirely synthetic graft materials. This is the first report of surgical experience with a new synthetic and absorbable dura substitute which has recently gained Food and Drug Administration (FDA) approval. Four patients underwent dural reconstruction with a new graft material after cranial neurosurgery when the dura was unrepairable directly. The synthetic graft material demonstrated satisfactory surgical qualities, was effective in dural repair, and no complications were attributable to the graft. Dural repair after craniotomy is an often desirable surgical outcome in neurosurgery. Surgeons seeking new graft materials may find this new absorbable, entirely synthetic material favorable for dural repair.
Publication Abnormal Large Central Occipital Emissary Vein: A Case Report and Review of Literature
(Cureus, 2016) Salem, Mohamed; Dolati, Parviz; Fusco, Matthew R; Ogilvy, Christopher; Thomas, AjithA detailed description of the anatomy of the central occipital emissary vein, its embryology, anatomy, and abnormal variations is not available in the literature. This is the first known case report. A 48-year-old female underwent cerebral angiography to rule out dural arterio-venous fistula. Her angiography revealed an abnormally large central occipital emissary vein originating from the torcula, penetrating the cranium and draining into the suboccipital venous plexus. We provide discussion of the case with a review of the related literature. This case and its attached radiological images introduce a new type of entity to the existing data about the cranial emissary veins.