Person: Aiello, Lloyd
Email Address
AA Acceptance Date
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
First Name
Name
Search Results
Publication Comparison of Time-Domain OCT and Fundus Photographic Assessments of Retinal Thickening in Eyes with Diabetic Macular Edema
(Association for Research in Vision and Ophthalmology (ARVO), 2008) Davis, Matthew D.; Bressler, Susan B.; Aiello, Lloyd; Bressler, Neil M.; Browning, David J.; Flaxel, Christina J.; Fong, Donald S.; Foster, William J.; Glassman, Adam R.; Hartnett, Mary Elizabeth R.; Kollman, Craig; Li, Helen K.; Qin, Haijing; Scott, Ingrid U.Purpose: To explore the correlation between optical coherence tomography (OCT) and stereoscopic fundus photographs (FP) for the assessment of retinal thickening (RT) in diabetic macular edema (DME) within a clinical trial. Methods: OCT, FP, and best corrected visual acuity (VA) measurements were obtained in both eyes of 263 participants in a trial comparing two photocoagulation techniques for DME. Correlation coefficients (r) were calculated comparing RT measured by OCT, RT estimated from FP, and VA. Principal variables were central subfield retinal thickness (CSRT) obtained from the OCT fast macular map and DME severity assessed by a reading center using a seven-step photographic scale combining the area of thickened retina within 1 disc diameter of the foveal center and thickening at the center. Results: Medians (quartiles) for retinal thickness within the center subfield by OCT at baseline increased from 236 (214, 264) μm in the lowest level of the photographic scale to 517 (455, 598) μm in the highest level (r = 0.67). However, CSRT interquartile ranges were broad and overlapping between FP scale levels, and there were many outliers. Correlations between either modality and VA were weaker (r = 0.57 for CSRT, and r = 0.47 for the FP scale). OCT appeared to be more reproducible and more sensitive to change in RT between baseline and 1 year than was FP. Conclusions: There was a moderate correlation between OCT and FP assessments of RT in patients with DME and slightly less correlation of either measure with VA. OCT and FP provide complementary information but neither is a reliable surrogate for VA.
Publication Effects of Dilation on Electronic-ETDRS Visual Acuity in Diabetic Patients
(Association for Research in Vision and Ophthalmology (ARVO), 2009) Sun, Jennifer; Aiello, Lloyd; Stockman, Margaret; Cavallerano, Jerry; Kopple, Ann; Eagan, Sharon; Qin, Haijing; Kollman, Craig; Beck, Roy W.; Glassman, Adam R.Objectives: To evaluate the effect of pupillary dilation on electronic-ETDRS visual acuity (EVA) in diabetic subjects and to assess post-dilation EVA as a surrogate for pre-dilation visual acuity (VA). Methods and Design: DRCR.net-protocol refraction and EVA were measured pre- and post-dilation in diabetic subjects by independent, masked examiners. Results: In 129 eyes of 66 subjects, median [25th, 75th percentiles] pre-dilation EVA score was 69 [54, 86] (Snellen-equivalent 20/40-1 [20/80-1, 20/20+1]). Pre-dilation VA was ≥20/20, 20/25-20/40, 20/50-20/80, and <20/80 in 29%, 19%, 26%, and 26% of eyes, respectively. Median EVA change post-dilation was -3 letters [-7, 0]. EVA change was ≥15 letters (≥ 3 ETDRS lines) in 9% of eyes and ≥10 letters (≥ 2 ETDRS lines) in 19% of eyes. Extent of change (range +12 to -25 letters) was associated with baseline VA. No relationship was identified between EVA change and gender, race, lens status, refractive error, DR severity, or primary cause of vision loss. Conclusions: In an optimized clinical trial setting, there is a decline in best-corrected EVA after dilation in diabetic subjects. The large range and magnitude of VA change preclude using post-dilation EVA as a surrogate for undilated VA.