Publication Design of a Motion Compensated Tissue Resection Catheter for Beating Heart Cardiac Surgery
(ASME International, 2011) Kesner, Samuel; Howe, RobertCardiac catheters allow clinicians to minimally invasively interact with the beating heart without stopping the heart or opening the chest. However, the fast motion of the intracardiac structures makes it difficult to modify and repair the tissue in a controlled and safe manner. To enable surgical procedures on the inside of the beating heart, we have developed an ultrasound-guided catheter system that virtually freezes the heart by compensating for the fast cardiac motions. The device presented in this paper is a resection tool that allows the catheter system to cut moving tissue, a key surgical task required for many intracardiac procedures including valve and leaflet repair. The motion tracking system is demonstrated in vivo and the tissue resection tool is evaluated by resecting tissue mounted on a cardiac motion simulator. The motion compensated catheter is shown to greatly improve the resection cut quality on the moving tissue target while reducing the forces experienced by the tissue by almost 80%
Publication Force control of flexible catheter robots for beating heart surgery
(Institute of Electrical and Electronics Engineers, 2011) Kesner, Samuel; Howe, RobertRecent developments in cardiac catheter technology promise to allow physicians to perform most cardiac interventions without stopping the heart or opening the chest. However, current cardiac devices, including newly developed catheter robots, are unable to accurately track and interact with the fast moving cardiac tissue without applying potentially damaging forces. This paper examines the challenges of implementing force control on a flexible robotic catheter. In particular, catheter friction and backlash must be compensated when controlling tissue interaction forces. Force controller designs are introduced and evaluated experimentally in a number of configurations. The controllers are based on the inner position loop force control approach where the position trajectory is adjusted to achieve a desired force on the target. Friction and backlash compensation improved force tracking up to 86% with residual RMS errors of 0.11 N while following a prerecorded cardiac tissue trajectory with accelerations of up to 3800 mm/s(^2). This performance provides sufficient accuracy to enable a wide range of beating heart surgical procedures.
Publication Patient-Specific Mitral Leaflet Segmentation from 4D Ultrasound
(Springer, 2011) Tenenholtz, Neil Arturo; Perrin, Douglas; Marx, Gerald; Del Nido, Pedro; Schneider, Robert J.; Howe, RobertSegmenting the mitral valve during closure and throughout a cardiac cycle from four dimensional ultrasound (4DUS) is important for creation and validation of mechanical models and for improved visualization and understanding of mitral valve behavior. Current methods of segmenting the valve from 4DUS either require extensive user interaction and initialization, do not maintain the valve geometry across a cardiac cycle, or are incapable of producing a detailed coaptation line and surface. We present a method of segmenting the mitral valve annulus and leaflets from 4DUS such that a detailed, patient-specific annulus and leaflets are tracked throughout mitral valve closure, resulting in a detailed coaptation region. The method requires only the selection of two frames from a sequence indicating the start and end of valve closure and a single point near a closed valve. The annulus and leaflets are first found through direct segmentation in the appropriate frames and then by tracking the known geometry to the remaining frames. We compared the automatically segmented meshes to expert manual tracings for both a normal and diseased mitral valve, and found an average difference of 0.59 ± 0.49mm, which is on the order of the spatial resolution of the ultrasound volumes (0.5–1.0mm/voxel).
Publication Design Principles for Rapid Prototyping Forces Sensors Using 3-D Printing
(Institute of Electrical and Electronics Engineers (IEEE), 2011) Kesner, Samuel; Howe, RobertForce sensors provide critical information about robot manipulators, manufacturing processes, and haptic interfaces. Commercial force sensors, however, are generally not adapted to specific system requirements, resulting in sensors with excess size, cost, and fragility. To overcome these issues, 3-D printers can be used to create components for the quick and inexpensive development of force sensors. Limitations of this rapid prototyping technology, however, require specialized design principles. In this paper, we discuss techniques for rapidly developing simple force sensors, including selecting and attaching metal flexures, using inexpensive and simple displacement transducers, and 3-D printing features to aid in assembly. These design methods are illustrated through the design and fabrication of a miniature force sensor for the tip of a robotic catheter system. The resulting force sensor prototype can measure forces with an accuracy of as low as 2% of the 10 N measurement range.
Publication Discriminating tissue stiffness with a haptic catheter: Feeling the inside of the beating heart
(Institute of Electrical and Electronics Engineers, 2011) Kesner, Samuel; Howe, RobertCatheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system.
Publication Anisotropic Mass-Spring Method Accurately Simulates Mitral Valve Closure from Image-Based Models
(Springer Science + Business Media, 2011) Hammer, Peter; Del Nido, Pedro; Howe, RobertHeart valves are functionally complex, making surgical repair difficult. Simulation-based surgical planning could facilitate repair, but current finite element studies are prohibitively slow for rapid, clinically-oriented simulations. An anisotropic, nonlinear mass-spring (M-S) model is used to approximate the behavior of valve leaflets and applied to fully image-based mitral valve models to simulate valve closure for fast applications like intraoperative surgical planning. This approach is used to simulate a technique used in valve repair and to assess the role of chordae in determining the closed configuration of the valve. Direct image-based comparison is used for validation. Results of M-S model simulations showed that it is possible to build fully image-based models of the mitral valve and to rapidly simulate closure with sub-millimeter accuracy. Chordae, which are presently difficult to image, are shown to be strong determinants of closed valve shape.
Publication Fast Interactive Simulations of Mitral Valve Repair
(2012) Tenenholtz, Neil Arturo; Hammer, Peter; Howe, RobertPublication Real-Time 4D Ultrasound Mosaicing and Visualization
(Springer Science + Business Media, 2011) Brattain, Laura; Howe, RobertIntra-cardiac 3D ultrasound imaging has enabled new minimally invasive procedures. Its narrow field of view, however, limits its efficacy in guiding beating heart procedures where geometrically complex and spatially extended moving anatomic structures are often involved. In this paper, we present a system that performs electrocardiograph gated 4D mosaicing and visualization of 3DUS volumes. Real-time operation is enabled by GPU implementation. The method is validated on phantom and porcine heart data.
Publication Design considerations for an active soft orthotic system for shoulder rehabilitation
(IEEE, 2011) Kesner, Samuel; Jentoft, Leif; Hammond, Frank; Howe, Robert; Popovic, MarkoStrokes affect over 750,000 people annually in the United States. This significant and disabling condition can result in paralysis that must be treated by regular sessions with a dedicated physical therapist in order to regain motor function. However, the use of therapists is expensive, in high demand, and requires patient travel to a rehabilitation clinic. We propose an inexpensive and wearable upper body orthotics system that can be used at home to provide the same level of rehabilitation as the current physical therapy standard of care. The system is composed of a soft orthotic device with an integrated cable actuation system that is worn over the upper body, a limb position sensing system, and an actuator package. This paper presents initial design considerations and the evaluation of a proof of concept system for shoulder joint rehabilitation. Through simulations and experimental evaluation, the system is shown to be adjustable, easily wearable, and adaptable to misalignment and anatomical variations. Insights provided by these initial studies will inform the development of a complete upper body orthotic system.
Publication Robotic catheter cardiac ablation combining ultrasound guidance and force control
(SAGE Publications, 2014) Kesner, Samuel; Howe, RobertCardiac catheters allow physicians to access the inside of the heart and perform therapeutic interventions without stopping the heart or opening the chest. However, conventional manual and actuated cardiac catheters are currently unable to precisely track and manipulate the intracardiac tissue structures because of the fast tissue motion and potential for applying damaging forces. This paper addresses these challenges by proposing and implementing a robotic catheter system that uses 3D ultrasound image guidance and force control to enable constant contact with a moving target surface in order to perform interventional procedures, such as intracardiac tissue ablation. The robotic catheter system, consisting of a catheter module, ablation and force sensing end effector, drive system, and image-guidance and control system, was commanded to apply a constant force against a moving target using a position-modulated force control method. The control system uses a combination of position tracking, force feedback, and friction and backlash compensation to achieve accurate and safe catheter–tissue interactions. The catheter was able to maintain a 1 N force on a moving motion simulator target under ultrasound guidance with 0.08 N RMS error. In a simulated ablation experiment, the robotic catheter was also able to apply a consistent force on the target while maintaining ablation electrode contact with 97% less RMS contact resistance variation than a passive mechanical equivalent. In addition, the use of force control improved catheter motion tracking by approximately 20%. These results demonstrate that 3D ultrasound guidance and force tracking allow the robotic system to maintain improved contact with a moving tissue structure, thus allowing for more accurate and repeatable cardiac procedures.