Person:
Hilberath, Jan N.

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Hilberath

First Name

Jan N.

Name

Hilberath, Jan N.

Search Results

Now showing 1 - 2 of 2
  • Thumbnail Image
    Publication
    Intraoperative Evaluation of Transmitral Pressure Gradients after Edge-to-Edge Mitral Valve Repair
    (Public Library of Science, 2013) Hilberath, Jan N.; Eltzschig, Holger K.; Shernan, Stanton; Worthington, Andrea H.; Aranki, Sary; Nowak-Machen, Martina
    Objective: Edge-to-edge repair of the mitral valve (MV) has been described as a viable option used for the surgical management of mitral regurgitation (MR). Based on the significant changes in MV geometry associated with this technique, we hypothesized that edge-to-edge MV repairs are associated with higher intraoperative transmitral pressure gradients (TMPG) compared to conventional methods. Methods: Patient records and intraoperative transesophageal echocardiography (TEE) examinations of 552 consecutive patients undergoing MV repair at a single institution over a three year period were assessed. After separation from cardiopulmonary bypass (CPB), peak and mean TMPG were recorded for each patient and subsequently analyzed. Results: 84 patients (15%) underwent edge-to-edge MV repair. Peak and mean TMPG were significantly higher compared to gradients in patients undergoing conventional repairs: 10.7±0.5 mmHg vs 7.1±0.2 mmHg; P<0.0001 and 4.3±0.2 mmHg vs 2.8±0.1 mmHg; P<0.0001. Only patients with mean TMPG ≥7 mmHg (n = 9) required prompt reoperation for iatrogenic mitral stenosis (MS). No differences in peak and mean TMPG were observed among edge-to-edge repairs performed in isolation, compared to those performed in combination with annuloplasty: 11.0±0.7 mmHg vs 10.3±0.6 mmHg and 4.4±0.3 mmHg vs 4.3±0.3 mmHg. There were no differences in TMPG between various types of annuloplasty techniques used in combination with the edge-to-edge repairs. Conclusions: Edge-to-edge MV repairs are associated with higher intraoperative peak and mean TMPG after separation from CPB compared to conventional repair techniques. Unless gradients are severely elevated, these findings are not necessarily suggestive of iatrogenic MS. Thus, in the immediate postoperative period mildly elevated TMPG can be expected and tolerated after edge-to-edge mitral repairs.
  • Thumbnail Image
    Publication
    Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function
    (Public Library of Science, 2015) Nowak-Machen, Martina; Hilberath, Jan N.; Rosenberger, Peter; Schmid, Eckhard; Memtsoudis, Stavros G.; Angermair, Johannes; Tuli, Jayshree K.; Shernan, Stanton
    Introduction: Intraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion. However, the effects of IABP on LV diastolic function have not been comprehensively investigated. Acute diastolic dysfunction has been linked to increased morbidity and mortality. The aim of this study was to examine the influence of IABP on LV diastolic dysfunction using standard TEE derived parameters. Methods: Intraoperative TEE was performed in 10 patients (mean age 65 ± 11 yrs) undergoing urgent coronary artery bypass graft surgery (CABG), who had received an IABP preoperatively. TEE derived measures of diastolic dysfunction included early to late transmitral Doppler inflow velocity ratio (E/A), deceleration time (Dt), pulmonary venous systolic to diastolic Doppler velocity ratio (S/D), transmitral propagation velocity (Vp), and the ratio of early to late mitral annular tissue Doppler velocities (e’/a’). Statistical analyses included the Wilcoxon Sign-Rank test, and a p<0.05 was considered significant. Results: Transmitral inflow E/A ratios increased significantly from 0.86 to 1.07 (p < 0.05), while Dt decreased significantly from 218 to 180 ms (p < 0.05) with the use of IABP. Significant increases in Vp (34 cm/s to 43 cm/s; p < 0.05), and e’/a’ (0.58 to 0.71; p < 0.05) suggested a favourable influence of intraaortic counterpulsation on diastolic function. Conclusion: The use of perioperative IABP significantly improves TEE derived parameters of diastolic function consistent with a favourable impact on LV relaxation in cardiac surgery patients undergoing CABG.