Hilberath, Jan N., Holger K. Eltzschig, Stanton K. Shernan, Andrea H. Worthington, Sary F. Aranki, and Martina Nowak-Machen. 2013. “Intraoperative Evaluation of Transmitral Pressure Gradients after Edge-to-Edge Mitral Valve Repair.” PLoS ONE 8 (9): e73617. doi:10.1371/journal.pone.0073617. http://dx.doi.org/10.1371/journal.pone.0073617.

Abstract

Objective: Edge-to-edge repair of the mitral valve (MV) has been described as a viable option used for the surgical management of mitral regurgitation (MR). Based on the significant changes in MV geometry associated with this technique, we hypothesized that edge-to-edge MV repairs are associated with higher intraoperative transmitral pressure gradients (TMPG) compared to conventional methods. Methods: Patient records and intraoperative transesophageal echocardiography (TEE) examinations of 552 consecutive patients undergoing MV repair at a single institution over a three year period were assessed. After separation from cardiopulmonary bypass (CPB), peak and mean TMPG were recorded for each patient and subsequently analyzed. Results: 84 patients (15%) underwent edge-to-edge MV repair. Peak and mean TMPG were significantly higher compared to gradients in patients undergoing conventional repairs: 10.7±0.5 mmHg vs 7.1±0.2 mmHg; P<0.0001 and 4.3±0.2 mmHg vs 2.8±0.1 mmHg; P<0.0001. Only patients with mean TMPG ≥7 mmHg (n = 9) required prompt reoperation for iatrogenic mitral stenosis (MS). No differences in peak and mean TMPG were observed among edge-to-edge repairs performed in isolation, compared to those performed in combination with annuloplasty: 11.0±0.7 mmHg vs 10.3±0.6 mmHg and 4.4±0.3 mmHg vs 4.3±0.3 mmHg. There were no differences in TMPG between various types of annuloplasty techniques used in combination with the edge-to-edge repairs. Conclusions: Edge-to-edge MV repairs are associated with higher intraoperative peak and mean TMPG after separation from CPB compared to conventional repair techniques. Unless gradients are severely elevated, these findings are not necessarily suggestive of iatrogenic MS. Thus, in the immediate postoperative period mildly elevated TMPG can be expected and tolerated after edge-to-edge mitral repairs.

Description

Research Data

Keywords

Medicine, Anatomy and Physiology, Cardiovascular System, Anesthesiology, Anesthesiology Monitoring, Cardiovascular, Valvular Disease, Critical Care and Emergency Medicine, Surgery, Anesthesia, Cardiothoracic Surgery, Cardiovascular Surgery, Minimally Invasive Surgery

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories