Person: Dohlman, Claes
Email Address
AA Acceptance Date
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
First Name
Name
Search Results
Publication A Novel Implantable Glaucoma Valve Using Ferrofluid
(Public Library of Science, 2013) Paschalis, Eleftherios I.; Chodosh, James; Sperling, Ralph A.; Salvador-Culla, Borja; Dohlman, ClaesPurpose To present a novel design of an implantable glaucoma valve based on ferrofluidic nanoparticles and to compare it with a well-established FDA approved valve. Setting: Massachusetts Eye & Ear Infirmary, Boston, USA. Methods: A glaucoma valve was designed using soft lithography techniques utilizing a water-immiscible magnetic fluid (ferrofluid) as a pressure-sensitive barrier to aqueous flow. Two rare earth micro magnets were used to calibrate the opening and closing pressure. In-vitro flow measurements were performed to characterize the valve and to compare it to Ahmed™ glaucoma valve. The reliability and predictability of the new valve was verified by pressure/flow measurements over a period of three months and X-ray diffraction (XRD) analysis over a period of eight weeks. In vivo assessment was performed in three rabbits. Results: In the in vitro experiments, the opening and closing pressures of the valve were 10 and 7 mmHg, respectively. The measured flow/pressure response was linearly proportional and reproducible over a period of three months (1.8 µl/min at 12 mmHg; 4.3 µl/min at 16 mmHg; 7.6 µl/min at 21 mmHg). X-ray diffraction analysis did not show oxidization of the ferrofluid when exposed to water or air. Preliminary in vivo results suggest that the valve is biocompatible and can control the intraocular pressure in rabbits. Conclusions: The proposed valve utilizes ferrofluid as passive, tunable constriction element to provide highly predictable opening and closing pressures while maintaining ocular tone. The ferrofluid maintained its magnetic properties in the aqueous environment and provided linear flow to pressure response. Our in-vitro tests showed reliable and reproducible results over a study period of three months. Preliminary in-vivo results were very promising and currently more thorough investigation of this device is underway.
Publication A Drug Delivery System for Administration of Anti–TNF-α Antibody
(The Association for Research in Vision and Ophthalmology, 2016) Robert, Marie-Claude; Frenette, Mathieu; Zhou, Chengxin; Yan, Yueran; Chodosh, James; Jakobiec, Frederick A.; Stagner, Anna M.; Vavvas, Demetrios; Dohlman, Claes; Paschalis, Eleftherios I.Purpose To describe the fabrication, evaluation, and preliminary in vivo safety of a new drug delivery system (DDS) for topical anti–TNF-α antibody administration. Methods: A DDS was fabricated using inverse template fabrication of a hydrophobic three-dimensional porous scaffold (100–300 μm in diameter porosity) loaded with 10% polyvinyl alcohol hydrogel carrying 5 mg/ml (weight/volume) of anti–TNF-α antibody. Drug-loaded DDS was sterilized with 25 kGy of gamma irradiation. Long-term in vitro antibody affinity and release was evaluated at room temperature or 37°C using enzyme-linked immunosorbent assay (ELISA) and protein fluorescence. In vivo clinical and histolopathological assessment was performed by subcutaneous implantation in BALB/c mice for 3 months. Results: Gamma irradiation, repeated dry/wet cycles, and storage at room temperature for 1 year or 37°C for 1 month had no deleterious effects on antibody affinity. Anti–TNF-α release was high during the first minutes of aqueous exposure, followed by stabilization and gradual, low-dose, antibody release over the next 30 days. Histopathologic evaluation of explanted DDS showed a fibrous pseudocapsule and a myxoid acute/chronic inflammation without granuloma formation surrounding the implants. Conclusions: Sustained local delivery of anti–TNF-α antibody is feasible using the described DDS, which provides stability of the enclosed antibody for up to 1 year of storage. Preliminary results show good in vivo tolerance following subcutaneous placement for 3 months. The proposed fabrication and sterilization process opens new possibilities for the delivery of biologic agents to the anterior surface of the eye. Translational Relevance The described DDS will facilitate the treatment of ocular surface diseases amenable to biologic therapy.
Publication Oral Acetazolamide after Boston Keratoprosthesis in Stevens Johnson Syndrome
(BioMed Central, 2012) Kumar, Radhika; Dohlman, Claes; Chodosh, JamesBackground: Stevens-Johnson syndrome/toxic epidermal necrolysis (SJS/TEN) is a rare but severe and sometimes fatal condition associated with exposure to medications; sulfamethoxazole is among the most common causes. We sought to address the safety of acetazolamide, a chemically related compound, in patients with prior SJS/TEN and glaucoma. A retrospective case series is described of patients at the Massachusetts Eye and Ear Infirmary who underwent keratoprosthesis surgery for corneal blindness from SJS/TEN, and later required oral acetazolamide for elevated intraocular pressure. Findings: Over the last 10 years, 17 patients with SJS/TEN received a Boston keratoprosthesis. Of these, 11 developed elevated intraocular pressure that required administration of oral acetazolamide. One of 11 developed a mild allergic reaction, but no patient experienced a recurrence of SJS/TEN or any severe adverse reaction. Conclusion: Although an increase in the rate of recurrent SJS/TEN due to oral acetazolamide would not necessarily be apparent after treating only 11 patients, in our series, acetazolamide administration was well tolerated without serious sequela.
Publication Titanium Coating of the Boston Keratoprosthesis
(The Association for Research in Vision and Ophthalmology, 2016) Salvador-Culla, Borja; Jeong, Kyung Jae; Kolovou, Paraskevi Evi; Chiang, Homer H.; Chodosh, James; Dohlman, Claes; Kohane, DanielPurpose We tested the feasibility of using titanium to enhance adhesion of the Boston Keratoprosthesis (B-KPro), ultimately to decrease the risk of implant-associated complications. Methods: Cylindrical rods were made of poly(methyl methacrylate) (PMMA), PMMA coated with titanium dioxide (TiO2) over a layer of polydopamine (PMMATiO2), smooth (Ti) and sandblasted (TiSB) titanium, and titanium treated with oxygen plasma (Tiox and TiSBox). Topography and surface chemistry were analyzed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). Adhesion force between rods and porcine corneas was measured ex vivo. Titanium sleeves, smooth and sandblasted, were inserted around the stem of the B-KPro and implanted in rabbits. Tissue adhesion to the stem was assessed and compared to an unmodified B-Kpro after 1 month. Results: X-ray photoelectron spectroscopy demonstrated successful deposition of TiO2 on polydopamine-coated PMMA. Oxygen plasma treatment did not change the XPS spectra of titanium rods (Ti and TiSB), although it increased their hydrophilicity. The materials did not show cell toxicity. After 14 days of incubation, PMMATiO2, smooth titanium treated with oxygen plasma (Tiox), and sandblasted titanium rods (TiSB, TiSBox) showed significantly higher adhesion forces than PMMA ex vivo. In vivo, the use of a TiSB sleeve around the stem of the B-KPro induced a significant increase in tissue adhesion compared to a Ti sleeve or bare PMMA. Conclusions: Sandblasted titanium sleeves greatly enhanced adherence of the B-KPro to the rabbit cornea. This approach may improve adhesion with the donor cornea in humans as well. Translational Relevance This approach may improve adhesion with donor corneas in humans.
Publication Colocalization of Galectin-3 With CD147 Is Associated With Increased Gelatinolytic Activity in Ulcerating Human Corneas
(The Association for Research in Vision and Ophthalmology, 2018) Cruzat, Andrea; Gonzalez-Andrades, Miguel; Mauris, Jérôme; Abusamra, Dina; Chidambaram, Preethi; Kenyon, Kenneth R.; Chodosh, James; Dohlman, Claes; Argueso, PabloPurpose Galectin-3 is a carbohydrate-binding protein known to promote expression of matrix metalloproteinases, a hallmark of ulceration, through interaction with the extracellular matrix metalloproteinase inducer CD147. The aim of this study was to investigate the distribution of galectin-3 in corneas of patients with ulcerative keratitis and to determine its relationship to CD147 and the presence of gelatinolytic activity. Methods: This was an observational case series involving donor tissue from 13 patients with active corneal ulceration and 6 control corneas. Fixed-frozen sections of the corneas were processed to localize galectin-3 and CD147 by immunofluorescence microscopy. Gelatinolytic activity was detected by in situ zymography. Results: Tissue from patients with active corneal ulceration showed a greater galectin-3 immunoreactivity in basal epithelia and stroma compared with controls. Immunofluorescence grading scores revealed increased colocalization of galectin-3 and CD147 in corneal ulcers at the epithelial–stromal junction and within fibroblasts. Quantitative analysis using the Manders' colocalization coefficient demonstrated significant overlap in corneas from patients with ulcerative keratitis (M1 = 0.29; M2 = 0.22) as opposed to control corneas (M1 = 0.01, P < 0.01; M2 = 0.02, P < 0.05). In these experiments, there was a significant positive correlation between the degree of galectin-3 and CD147 colocalization and the presence of gelatinolytic activity. Conclusions: Our results indicate that concomitant stimulation and colocalization of galectin-3 with CD147 are associated with increased gelatinolytic activity in the actively ulcerating human cornea and suggest a mechanism by which galectin-3 may contribute to the degradation of extracellular matrix proteins during ulceration.