Person: Wong, C
Email Address
AA Acceptance Date
Birth Date
Search Results
Publication BICEP2 III: Instrumental Systematics
(IOP Publishing, 2015) Ade, P. A. R.; Aikin, R. W.; Barkats, Denis; Benton, S. J.; Bischoff, Colin; Bock, J. J.; Brevik, J. A.; Buder, I; Bullock, E.; Dowell, C. D.; Duband, L.; Filippini, J. P.; Fliescher, S.; Golwala, S. R.; Halpern, M.; Hasselfield, M.; Hildebrandt, S. R.; Hilton, G. C.; Irwin, K. D.; Karkare, Kirit Sukrit; Kaufman, J. P.; Keating, B. G.; Kernasovskiy, S. A.; Kovac, John; Kuo, C. L.; Leitch, E. M.; Lueker, M.; Netterfield, C. B.; Nguyen, H. T.; O’Brient, R.; IV, R. W. Ogburn; Orlando, Abigail; Pryke, C; Richter, Sonja Valeska; Schwarz, R.; Sheehy, C. D.; Staniszewski, Z. K.; Sudiwala, R. V.; Teply, G. P.; Tolan, J. E.; Turner, A. D.; Vieregg, A. G.; Wong, C; Yoon, K. W.In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call "deprojection," for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ~10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10−3.
Publication Antenna-coupled TES Bolometers used in BICEP2, Keck Array, and SPIDER
(IOP Publishing, 2015) Ade, P. A. R.; Aikin, R. W.; Amiri, M.; Barkats, D.; Benton, S. J.; Bischoff, Colin; Bock, J. J.; Bonetti, J. A.; Brevik, J. A.; Buder, I; Bullock, E.; Chattopadhyay, G.; Davis, G.; Day, P. K.; Dowell, C. D.; Duband, L.; Filippini, J. P.; Fliescher, S.; Golwala, S. R.; Halpern, M.; Hasselfield, M.; Hildebrandt, S. R.; Hilton, G. C.; Hristov, V.; Hui, H.; Irwin, K. D.; Jones, W. C.; Karkare, Kirit Sukrit; Kaufman, J. P.; Keating, B. G.; Kefeli, S.; Kernasovskiy, S. A.; Kovac, John; Kuo, C. L.; LeDuc, H. G.; Leitch, E. M.; Llombart, N.; Lueker, M.; Mason, P.; Megerian, K.; Moncelsi, L.; Netterfield, C. B.; Nguyen, H. T.; O’Brient, R.; IV, R. W. Ogburn; Orlando, A.; Pryke, C; Rahlin, A. S.; Reintsema, C. D.; Richter, S.; Runyan, M. C.; Schwarz, R.; Sheehy, C. D.; Staniszewski, Z. K.; Sudiwala, R. V.; Teply, G. P.; Tolan, J. E.; Trangsrud, A.; Tucker, R. S.; Turner, A. D.; Vieregg, A. G.; Weber, A.; Wiebe, D. V.; Wilson, P.; Wong, C; Yoon, K. W.; Zmuidzinas, J.; undefined, undefinedWe have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at 95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ~0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the SPIDER instrument, and development of this technology is ongoing.
Publication BICEP2. II. Experiment and three-year data set
(IOP Publishing, 2014) Ade, P. A. R.; Aikin, R. W.; Amiri, M.; Barkats, Denis; Benton, S. J.; Bischoff, Colin; Bock, J. J.; Brevik, J. A.; Buder, I.; Bullock, E.; Davis, G.; Day, P. K.; Dowell, C. D.; Duband, L.; Filippini, J. P.; Fliescher, S.; Golwala, S. R.; Halpern, M.; Hasselfield, M.; Hildebrandt, S. R.; Hilton, G. C.; Irwin, K. D.; Karkare, Kirit Sukrit; Kaufman, J. P.; Keating, B. G.; Kernasovskiy, S. A.; Kovac, John; Kuo, C. L.; Leitch, E. M.; Llombart, N.; Lueker, M.; Netterfield, C. B.; Nguyen, H. T.; O, R.; Ogburn, R. W.; Orlando, Abigail; Pryke, C; Reintsema, C. D.; Richter, S.; Schwarz, R.; Sheehy, C. D.; Staniszewski, Z. K.; Story, K. T.; Sudiwala, R. V.; Teply, G. P.; Tolan, J. E.; Turner, A. D.; Vieregg, A. G.; Wilson, P.; Wong, C; Yoon, K. W.We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1°-5°(l = 40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26 cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μ {K}\sqrt{{s}}. The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.'2 μK) over an effective area of 384 deg2 within a 1000 deg2 field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.
Publication bicep2/Keck Array. IV. Optical Characterization and Performance of the Bicep2 and Keck Array Experiments
(IOP Publishing, 2015) Ade, P. A. R.; Aikin, R. W.; Barkats, Denis; Benton, S. J.; Bischoff, Colin; Bock, J. J.; Bradford, K. J.; Brevik, J. A.; Buder, I; Bullock, E.; Dowell, C. D.; Duband, L.; Filippini, J. P.; Fliescher, S.; Golwala, S. R.; Halpern, M.; Hasselfield, M.; Hildebrandt, S. R.; Hilton, G. C.; Hui, H.; Irwin, K. D.; Kang, J. H.; Karkare, Kirit Sukrit; Kaufman, J. P.; Keating, B. G.; Kefeli, S.; Kernasovskiy, S. A.; Kovac, John; Kuo, C. L.; Leitch, E. M.; Lueker, M.; Megerian, K. G.; Netterfield, C. B.; Nguyen, H. T.; O’Brient, R.; IV, R. W. Ogburn; Orlando, A.; Pryke, C; Richter, Sonja Valeska; Schwarz, R.; Sheehy, C. D.; Staniszewski, Z. K.; Sudiwala, R. V.; Teply, G. P.; Thompson, K.; Tolan, J. E.; Turner, A. D.; Vieregg, A. G.; Weber, A. C.; Wong, C; Yoon, K. W.bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.
Publication Bicep2/keck Array. Vii. Matrix Basede/bseparation Applied to Bicep2 and the Keck Array
(American Astronomical Society, 2016) Ade, P. A. R.; Ahmed, Z.; Aikin, R. W.; Alexander, Kate; Barkats, Denis; Benton, S. J.; Bischoff, Colin; Bock, J. J.; Bowens-Rubin, Rachel; Brevik, J. A.; Buder, I; Bullock, E.; Buza, Victor; Connors, Jake Anthony; Crill, B. P.; Duband, L.; Dvorkin, Cora; Filippini, J. P.; Fliescher, S.; Grayson, J.; Halpern, M.; Harrison, Sarah; Hildebrandt, S. R.; Hilton, G. C.; Hui, H.; Irwin, K. D.; Kang, J.; Karkare, Kirit Sukrit; Karpel, E.; Kaufman, J. P.; Keating, B. G.; Kefeli, S.; Kernasovskiy, S. A.; Kovac, John; Kuo, C. L.; Leitch, E. M.; Lueker, M.; Megerian, K. G.; Namikawa, T.; Netterfield, C. B.; Nguyen, H. T.; O’Brient, R.; IV, R. W. Ogburn; Orlando, A.; Pryke, C.; Richter, S.; Schwarz, R.; Sheehy, C. D.; Staniszewski, Z. K.; Steinbach, B.; Sudiwala, R. V.; Teply, G. P.; Thompson, K. L.; Tolan, J. E.; Tucker, C.; Turner, A. D.; Vieregg, A. G.; Weber, A. C.; Wiebe, D. V.; Willmert, J.; Wong, C; Wu, W. L. K.; Yoon, K. W.A linear polarization field on the sphere can be uniquely decomposed into an E-mode and a B-mode component. These two components are analytically defined in terms of spin-2 spherical harmonics. Maps that contain filtered modes on a partial sky can also be decomposed into E-mode and B-mode components. However, the lack of full sky information prevents orthogonally separating these components using spherical harmonics. In this paper, we present a technique for decomposing an incomplete map into E and B-mode components using E and B eigenmodes of the pixel covariance in the observed map. This method is found to orthogonally define E and B in the presence of both partial sky coverage and spatial filtering. This method has been applied to the Bicep2 and the Keck Array maps and results in reducing E to B leakage from ΛCDM E-modes to a level corresponding to a tensor-to-scalar ratio of