Person:

Steigner, Michael

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Steigner

First Name

Michael

Name

Steigner, Michael

Search Results

Now showing 1 - 10 of 24
  • Publication

    Tumor Encasement of the Right Coronary Artery: Role of Anatomic and Functional Imaging in Diagnosis and Therapeutic Management

    (Bentham Open, 2014) Juan, Yu-Hsiang; Chatzizisis, Yiannis; Saboo, Sachin S; Rocha, Tatiana; Steigner, Michael

    We presented two rare cases of mediastinal tumor encasing the right coronary artery (RCA), one with recurrent metastatic thymoma and another with primary poorly differentiated neoplasm. Different degrees and locations of RCA involvement were noted. The treatment approach varied from conservative to surgical. Coronary artery involvement by mediastinal tumors is important to be investigated with imaging as it may guide the surgical planning.

  • Publication

    Reduced Radiation Exposure for Face Transplant Surgical Planning Computed Tomography Angiography

    (Public Library of Science, 2013) Schultz, Kurt; George, Elizabeth; Mullen, Katherine; Steigner, Michael; Mitsouras, Dimitrios; Bueno, Ericka M.; Pomahac, Bohdan; Rybicki, Frank John; Kumamaru, Kanako

    Objective: To test the hypothesis that wide area detector face transplant surgical planning CT angiograms with simulated lower radiation dose and iterative reconstruction (AIDR3D) are comparable in image quality to those with standard tube current and filtered back projection (FBP) reconstruction. Materials and Methods The sinograms from 320-detector row CT angiography of four clinical candidates for face transplantation were processed utilizing standard FBP, FBP with simulated 75, 62, and 50% tube current, and AIDR3D with corresponding dose reduction. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured at muscle, fat, artery, and vein. Image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. Results: Compared to FBP, the median SNR and CNR for AIDR3D images were higher at all sites for all 4 different tube currents. The AIDR3D with simulated 50% tube current achieved comparable SNR and CNR to FBP with standard dose (median muscle SNR: 5.77 vs. 6.23; fat SNR: 6.40 vs. 5.75; artery SNR: 43.8 vs. 45.0; vein SNR: 54.9 vs. 55.7; artery CNR: 38.1 vs. 38.6; vein CNR: 49.0 vs. 48.7; all p-values >0.19). The interobserver agreement in the image quality score was good (weighted κ = 0.7). The overall score and the scores for smaller arteries were significantly lower when FBP with 50% dose reduction was used. The AIDR3D reconstruction images with 4 different simulated doses achieved a mean score ranging from 3.68 to 3.82 that were comparable to the scores from images reconstructed using FBP with original dose (3.68–3.77). Conclusions: Simulated radiation dose reduction applied to clinical CT angiography for face transplant planning suggests that AIDR3D allows for a 50% reduction in radiation dose, as compared to FBP, while preserving image quality.

  • Publication

    Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)

    (Springer Netherlands, 2013) Chen, Marcus Y.; Steigner, Michael; Leung, Steve W.; Kumamaru, Kanako K.; Schultz, Kurt; Mather, Richard T.; Arai, Andrew E.; Rybicki, Frank John

    To compare the image quality of coronary CT angiography (CTA) studies between standard filtered back projection (FBP) and adaptive iterative dose reduction in three-dimensions (AIDR3D) reconstruction using CT noise additional software to simulate reduced radiation exposure. Images from 93 consecutive clinical coronary CTA studies were processed utilizing standard FBP, FBP with 50 % simulated dose reduction (FBP50 %), and AIDR3D with simulated 50 % dose reduction (AIDR50 %). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured within 5 regions-of-interest, and image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. Compared to FBP, the SNR measured from the AIDR50 % images was similar or higher (airway: 38.3 ± 12.7 vs. 38.5 ± 14.5, p = 0.81, fat: 5.5 ± 1.9 vs. 5.4 ± 2.0, p = 0.20, muscle: 3.2 ± 1.2 vs. 3.1 ± 1.3, p = 0.38, aorta: 22.6 ± 9.4 vs. 20.2 ± 9.7, p < 0.0001, liver: 2.7 ± 1.0 vs. 2.3 ± 1.1, p < 0.0001), while the SNR of the FBP50 % images were all lower (p values < 0.0001). The CNR measured from AIDR50 % images was also higher than that from the FBP images for the aorta relative to muscle (20.5 ± 9.0 vs. 18.3 ± 9.2, p < 0.0001). The interobserver agreement in the image quality score was excellent (κ = 0.82). The quality score was significantly higher for the AIDR50 % images compared to the FBP images (3.6 ± 0.6 vs. 3.3 ± 0.7, p = 0.004). Simulated radiation dose reduction applied to clinical coronary CTA images suggests that a 50 % reduction in radiation dose can be achieved with adaptive iterative dose reduction software with image quality that is at least comparable to images acquired at standard radiation exposure and reconstructed with filtered back projection.

  • Publication

    Feasibility study of electrocardiographic and respiratory gated, gadolinium enhanced magnetic resonance angiography of pulmonary veins and the impact of heart rate and rhythm on study quality

    (BioMed Central, 2014) Groarke, John; Waller, Alfonso H; Vita, Tomas S; Michaud, Gregory F.; Di Carli, Marcelo; Blankstein, Ron; Kwong, Raymond; Steigner, Michael

    Background: We aimed to assess the feasibility of 3 dimensional (3D) respiratory and ECG gated, gadolinium enhanced magnetic resonance angiography (MRA) on a 3 Tesla (3 T) scanner for imaging pulmonary veins (PV) and left atrium (LA). The impact of heart rate (HR) and rhythm irregularity associated with atrial fibrillation (AF) on image and segmentation qualities were also assessed. Methods: 101 consecutive patients underwent respiratory and ECG gated (ventricular end systolic window) MRA for pre AF ablation imaging. Image quality (assessed by PV delineation) was scored as 1 = not visualized, 2 = poor, 3 = good and 4 = excellent. Segmentation quality was scored on a similar 4 point scale. Signal to noise ratios (SNRs) were calculated for the LA, LA appendage (LAA), and PV. Contrast to noise ratios (CNRs) were calculated between myocardium and LA, LAA and PV, respectively. Associations between HR/rhythm and quality metrics were assessed. Results: 35 of 101 (34.7%) patients were in AF at time of MRA. 100 (99%) patients had diagnostic studies, and 91 (90.1%) were of good or excellent quality. Overall, mean ± standard deviation (SD) image quality score was 3.40 ± 0.69. Inter observer agreement for image quality scores was substantial, (kappa = 0.68; 95% confidence interval (CI): 0.46, 0.90). Neither HR adjusting for rhythm [odds ratio (OR) = 1.03, 95% CI = 0.98,1.09; p = 0.22] nor rhythm adjusting for HR [OR = 1.25, 95% CI = 0.20, 7.69; p = 0.81] demonstrated association with image quality. Similarly, SNRs and CNRs were largely independent of HR after adjusting for rhythm. Segmentation quality scores were good or excellent for 77.3% of patients: mean ± SD score = 2.91 ± 0.63, and scores did not significantly differ by baseline rhythm (p = 0.78). Conclusions: 3D respiratory and ECG gated, gadolinium enhanced MRA of the PVs and LA on a 3 T system is feasible during ventricular end systole, achieving high image quality and high quality image segmentation when imported into electroanatomic mapping systems. Quality is independent of HR and heart rhythm for this free breathing, radiation free, alternative strategy to current MRA or CT based approaches, for pre AF ablation imaging of PVs and LA.

  • Publication

    Superior Vena Cava Syndrome Associated with Right-to-Left Shunt through Systemic-to-Pulmonary Venous Collaterals

    (The Korean Society of Radiology, 2014) Juan, Yu-Hsiang; Saboo, Sachin S.; Anand, Vishal; Chatzizisis, Yiannis S.; Lin, Yu-Ching; Steigner, Michael

    Superior vena cava (SVC) obstruction is associated with the gradual development of venous collaterals. We present a rare form of systemic-to-pulmonary subpleural collateral pathway that developed in the bridging subpleural pulmonary veins in a 54-year-old woman with complete SVC obstruction. This uncommon collateral pathway represents a rare form of acquired right-to-left shunt due to previous pleural adhesions with an increased risk of stroke due to right-to-left venous shunting, which requires lifelong anticoagulation.

  • Publication

    Effect of Sleep Apnea and Continuous Positive Airway Pressure on Cardiac Structure and Recurrence of Atrial Fibrillation

    (Blackwell Publishing Ltd, 2013) Neilan, Tomas; Farhad, Hoshang; Dodson, John A.; Shah, Ravi; Abbasi, Siddique A.; Bakker, Jessie P.; Michaud, Gregory F.; van der Geest, Rob; Blankstein, Ron; Steigner, Michael; John, Roy M.; Jerosch‐Herold, Michael; Malhotra, Atul; Kwong, Raymond Y.

    Background: Sleep apnea (SA) is associated with an increased risk of atrial fibrillation (AF). We sought to determine the effect of SA on cardiac structure in patients with AF, whether therapy for SA was associated with beneficial cardiac structural remodelling, and whether beneficial cardiac structural remodelling translated into a reduced risk of recurrence of AF after pulmonary venous isolation (PVI). Methods and Results: A consecutive group of 720 patients underwent a cardiac magnetic resonance study before PVI. Patients with SA (n=142, 20%) were more likely to be male, diabetic, and hypertensive and have an increased pulmonary artery pressure, right ventricular volume, atrial dimensions, and left ventricular mass. Treated SA was defined as duration of continuous positive airway pressure therapy of >4 hours per night. Treated SA patients (n=71, 50%) were more likely to have paroxysmal AF, a lower blood pressure, lower ventricular mass, and smaller left atrium. During a follow‐up of 42 months, AF recurred in 245 patients. The cumulative incidence of AF recurrence was 51% in patients with SA, 30% in patients without SA, 68% in patients with untreated SA, and 35% in patients with treated SA. In a multivariable model, the presence of SA (hazard ratio 2.79, CI 1.97 to 3.94, P<0.0001) and untreated SA (hazard ratio 1.61, CI 1.35 to 1.92, P<0.0001) were highly associated with AF recurrence. Conclusions: Patients with SA have an increased blood pressure, pulmonary artery pressure, right ventricular volume, left atrial size, and left ventricular mass. Therapy with continuous positive airway pressure is associated with lower blood pressure, atrial size, and ventricular mass, and a lower risk of AF recurrence after PVI.

  • Publication

    Anomalous origin of the coronary artery arising from the opposite sinus: prevalence and outcomes in patients undergoing coronary CTA

    (Oxford University Press (OUP), 2016) Cheezum, Michael K.; Ghoshhajra, Brian; Bittencourt, Marcio S.; Hulten, Edward A.; Bhatt, Ami; Mousavi, Negareh; Shah, Nishant R.; Valente, Anne Marie; Rybicki, Frank John; Steigner, Michael; Hainer, Jon; MacGillivray, Thomas; Hoffmann, Udo; Abbara, Suhny; Di Carli, Marcelo; DeFaria Yeh, Doreen; Landzberg, Michael; Liberthson, Richard; Blankstein, Ron

    Aims The impact of coronary computed tomographic angiography (CTA) on management of anomalous origin of the coronary artery arising from the opposite sinus (ACAOS) remains uncertain. We examined the prevalence, anatomical characterization, and outcomes of ACAOS patients undergoing CTA. Methods and results Among 5991 patients referred for CTA at two tertiary hospitals between January 2004 and June 2014, we identified 103 patients (1.7% prevalence) with 110 ACAOS vessels. Mean age was 52 years (range 5–83, 63% male), with 55% previously known ACAOS and 45% discovered on CTA. ACAOS subtypes included: 39% interarterial (n = 40 anomalous right coronary artery, n = 3 anomalous left coronary artery), 38% retroaortic, 15% subpulmonic, 5% prepulmonic, and 2% other. ACAOS patients were assessed for symptoms, ischaemic test results, revascularization, all-cause or cardiovascular (CV) death, and myocardial infarction. CTAs were reviewed for ACAOS course, take-off height and angle, length and severity of proximal narrowing, intramural course, and obstructive coronary artery disease (CAD). In follow-up (median 5.8 years), there were 20 surgical revascularizations and 3 CV deaths. After adjusting for obstructive CAD (n = 21/103, 20%), variables associated with ACAOS revascularization included the following: CV symptoms, proximal vessel narrowing ≥50%, length of narrowing >5.4 mm, and an interarterial course. Conclusion The prevalence of ACAOS on CTA was 1.7%, including 45% of cases discovered incidentally. CTA provided excellent characterization of ACAOS features associated with coronary revascularization, including the length and severity of proximal vessel narrowing.

  • Publication

    Contrast inhomogeneity in CT angiography of the abdominal aortic aneurysm

    (Elsevier BV, 2016) George, Elizabeth; Giannopoulos, Andreas A.; Aghayev, Ayaz; Rohatgi, Saurabh; Imanzadeh, Amir; Antoniadis, Antonios P.; Kumamaru, Kanako; Chatzizisis, Yiannis; Dunne, Ruth Mary; Steigner, Michael; Hanley, Michael; Gravereaux, Edwin; Rybicki, Frank John; Mitsouras, Dimitrios

    Background

    If undetected, infrarenal Abdominal Aortic Aneurysm (AAA) growth can lead to rupture, a high-mortality complication. Some AAA patients exhibit inhomogeneous luminal contrast attenuation at first-pass CT angiography (CTA). This study assesses the association between this observation and aneurysm growth.

    Methods

    Sixty-seven consecutive pre-repair AAA CTAs were included in this retrospective study. The “Gravitational Gradient” (GG), defined as the ratio of the mean attenuation in a region-of-interest placed posteriorly to that in a region-of-interest placed anteriorly within the lumen of the aortic aneurysm on a single axial slice, and the maximum aneurysm diameter were measured from each CT data set. “AAA Contrast Inhomogeneity” was defined as the absolute value of the difference between the GG and 1.0. Univariate and multivariate logistic regression was used to assess the association of aneurysm growth >0.4 and >1.0 cm/year to AAA Contrast Inhomogeneity, aneurysm diameter, patient characteristics and cardiovascular co-morbidities.

    Results

    AAA Contrast Inhomogeneity was not correlated to aneurysm diameter (p=0.325). In multivariable analysis that included initial aneurysm diameter and AAA Contrast Inhomogeneity, both factors were significantly associated with rapid aneurysm growth (initial diameter: p=0.0029 and 0.011, and, AAA Contrast Inhomogeneity: p=0.045 and 0.048 for growth >0.4 cm/year and >1 cm/year respectively).

    Conclusions

    AAA Contrast Inhomogeneity is a common observation in first-pass CTA. It is associated with rapid aneurysm growth, independent of and incremental to aneurysm diameter.

  • Publication

    Symptomatic coronary cameral fistula

    (Medknow, 2015) Nagpal, Prashant; Khandelwal, Ashish; Saboo, SachinS; Garg, Gunjan; Steigner, Michael

    Coronary cameral fistula is a rare entity and is characterized by an abnormal communication between coronary artery and a cardiac chamber. It is usually congenital and asymptomatic in majority of patients. If symptomatic the patients usually present in childhood. We present a case of 45-year-old male who presented with anginal chest pain and dyspnea on exertion for last 1 year. His exercise treadmill test was positive for ischemic changes and ECG-gated contrast enhanced CT was done for further evaluation. CT showed a large right coronary artery to right atrium fistula. It also ruled out any coronary atherosclerosis as reason for chest pain and ischemic symptoms on exercise treadmill test. The fistula was successfully closed by surgery and there was resolution of chest pain and dyspnea.

  • Publication

    Risk Stratification by Regadenoson Stress Magnetic Resonance Imaging in Patients With Known or Suspected Coronary Artery Disease

    (Elsevier BV, 2014) Abbasi, Siddique Akbar; Heydari, Bobak; Shah, Ravi; Murthy, Venkatesh; Zhang, Ying-Yi; Blankstein, Ron; Steigner, Michael; Jerosch-Herold, Michael; Kwong, Raymond

    The aim of this study was to investigate the association between major adverse cardiovascular events (MACEs) and inducible ischemia on regadenoson cardiac magnetic resonance (CMR) myocardial perfusion imaging (MPI) performed at 3.0 T. Regadenoson stress CMR MPI is increasingly used to assess patients with suspected ischemia; however, its value in patient prognostication and risk reclassification is only emerging. A total of 346 patients with suspected ischemia who were referred for regadenoson CMR were studied. The prognostic association of presence of inducible ischemia by CMR with MACEs was determined. In addition, we assessed the extent of net reclassification improvement by CMR beyond a clinical risk model. There were 52 MACEs during a median follow-up period of 1.9 years. Patients with inducible ischemia were fourfold more likely to experience MACEs (hazard ratio, 4.14, 95% confidence interval 2.37 to 7.24, p <0.0001). In the best overall model, presence of inducible ischemia conferred a 2.6-fold increased hazard for MACEs adjusted to known clinical risk markers (adjusted hazard ratio 2.59, 95% confidence interval 1.30 to 5.18, p = 0.0069). Patients with no inducible ischemia experienced a low rate of cardiac death and myocardial infarction (0.6% per patient-year), whereas those with inducible ischemia had an annual event rate of 3.2%. Net reclassification improvement across risk categories (low <5%, intermediate 5% to 10%, and high >10%) by CMR was 0.29 (95% confidence interval 0.15 to 0.44), and continuous net reclassification improvement was 0.58. In conclusion, in patients with clinical suspicion of myocardial ischemia, regadenoson stress CMR MPI provides robust risk stratification. CMR MPI negative for ischemia was associated with a very low annual rate of hard cardiac events. In addition, CMR MPI provides effective risk reclassification in a substantial proportion of patients.