  • Publication

    Improved 3D late gadolinium enhancement MRI for patients with arrhythmia or heart rate variability

    (BioMed Central, 2013) Weingärtner, Sebastian; Akcakaya, Mehmet; Berg, Sophie; Kissinger, Kraig V; Manning, Warren; Nezafat, Reza
  • Publication

    Accelerated three-dimensional free-breathing first pass cardiac perfusion at 1.5T

    (BioMed Central, 2013) Akcakaya, Mehmet; Basha, Tamer A; Foppa, Murilo; Kissinger, Kraig V; Manning, Warren; Nezafat, Reza
  • Publication

    Heart-rate independent myocardial T1-mapping using combined saturation and inversion preparation pulses

    (BioMed Central, 2013) Weingärtner, Sebastian; Akcakaya, Mehmet; Berg, Sophie; Kissinger, Kraig V; Manning, Warren; Nezafat, Reza
  • Publication

    Improved accelerated breath-hold radial cine image reconstruction by acquiring additional free-breathing data between breath-holds

    (BioMed Central, 2012) Nam, Seunghoon; Akcakaya, Mehmet; Kwak, Yongjun; Goddu, Beth; Kissinger, Kraig V; Manning, Warren; Tarokh, Vahid; Nezafat, Reza
  • Publication

    Left Atrial Scar Assessment Using Imaging With Isotropic Spatial Resolution and Compressed Sensing

    (BioMed Central, 2012) Akcakaya, Mehmet; Hong, Susie; Chan, Raymond Ho Ming; Basha, Tamer A; Moghari, Mehdi; Kissinger, Kraig V; Goddu, Beth; Josephson, Mark; Manning, Warren; Nezafat, Reza

    Summary. We assess left atrial scar using late gadolinium enhancement (LGE) with isotropic spatial resolution of (1.4^3 mm^3) by using highly accelerated LOST [1] reconstruction. Background. Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia [2]. Pulmonary vein isolation (PVI) using radiofrequency (RF)-ablation is the leading treatment for AF. Recently, LGE imaging of the LA has been used to identify atrial wall scar due to RF-ablation [3]. However, current LGE methods have limited spatial resolution that substantially impact assessment of scar in the complex geometry of PVs and LA. In this study, we sought to utilize prospective random k-space sampling and LOST [1] for accelerated LGE imaging, where reduction in imaging time was traded-off for improved isotropic spatial-resolution. Methods. 23 patients with history of AF (6 females, (58.1 \pm 9.6) years, 9 pre-PVI, 2 with history of PVI; 8 post-PVI; 3 with both pre and post-PVI) were recruited for this study. LGE images were acquired 10-to-20 minutes after bolus infusion of 0.2 mmol/kg Gd-DTPA. Free-breathing ECG-triggered navigator-gated inversion-recovery GRE sequences were used for all acquisitions ((TR/TE/ \alpha = 5.2/2.6ms/25°, FOV=320×320×100mm)). The PV inflow artifact reduction technique in [4] was also utilized. For each patient, a standard non-isotropic 3D LGE scan ((1.4×1.4×4.0mm^3)) and a 3-fold-accelerated highresolution 3D LGE scan ((1.4^3 mm^3)) were performed, with randomized acquisition order. For random undersampling, central k-space (45×35 in ky-kz) was fullysampled, edges randomly discarded, and phase reordering performed as in [5]. Acquisition times were ~4 mins assuming 100% scan-efficiency at 70bpm for both scans. All undersampled data were reconstructed offline using LOST [1]. LOST-reconstructed high-resolution, and standard LGE images were scored by two blinded readers for diagnostic value, presence of LGE(yes/no); and image quality in axial(Ax), coronal(Co) and sagittal (Sa) views (1=poor,4=excellent). Results. Three cases were declared non-diagnostic due to contrast-washout and imperfect inversion-time. LGE was visually present in 14 of the remaining 20 patients based on standard-LGE images, and 12 based on LOST-reconstructed ones (disagreement on one pre- and one postPVI patient). Figure 1 and 2 show comparisons of isotropic vs. non-isotropic LGE images in two patients. Image scores for LOST-LGE: ( Ax=2.90 \pm 0.70, Sa=3.33 \pm 0.66, Co=3.00 \pm 0.63); and standard LGE: (Ax=3.76 \pm 0.54, Sa=2.48 \pm 0.60, Co=2.24 \pm 0.44), where differences were significant in all views. Conclusions. LOST allows isotropic spatial-resolution in LGE for assessment of LA and PV scar. Isotropic resolution allows reformatting LGE images in any orientation and facilitates assessment of scar. Further clinical study is needed to assess if the improved spatial resolution will impact the diagnostic interpretation of data.

  • Publication

    Improved Late Gadolinium Enhancement Imaging of Left Ventricle with Isotropic Spatial Resolution

    (BioMed Central, 2012) Akcakaya, Mehmet; Rayatzadeh, Hussein; Hong, Susie; Hauser, Thomas; Chan, Raymond Ho Ming; Basha, Tamer A; Kissinger, Kraig V; Goddu, Beth; Manning, Warren; Nezafat, Reza
  • Publication

    Free-Breathing Late Gadolinium Enhancement CMR with a Fixed Short Scan Time Using CosMo

    (BioMed Central, 2012) Moghari, Mehdi; Rayatzadeh, Hussein; Hong, Susie; Chan, Raymond H.; Akcakaya, Mehmet; Goddu, Beth; Goepfert, Lois A; Kissinger, Kraig V; Manning, Warren; Nezafat, Reza

    To evaluate the performance of compressed sensing for motion correction (CosMo) [1] in compensating the respiratory motion of the heart in 3D late gadolinium enhancement (LGE) CMR.

  • Publication

    Accelerated free breathing ECG triggered contrast enhanced pulmonary vein magnetic resonance angiography using compressed sensing

    (BioMed Central, 2014) Roujol, Sébastien; Foppa, Murilo; Basha, Tamer A; Akcakaya, Mehmet; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Nezafat, Reza

    Background: To investigate the feasibility of accelerated electrocardiogram (ECG)-triggered contrast enhanced pulmonary vein magnetic resonance angiography (CE-PV MRA) with isotropic spatial resolution using compressed sensing (CS). Methods: Nineteen patients (59 ± 13 y, 11 M) referred for MR were scanned using the proposed accelerated free breathing ECG-triggered 3D CE-PV MRA sequence (FOV = 340 × 340 × 110 mm3, spatial resolution = 1.5 × 1.5 × 1.5 mm3, acquisition window = 140 ms at mid diastole and CS acceleration factor = 5) and a conventional first-pass breath-hold non ECG-triggered 3D CE-PV MRA sequence. CS data were reconstructed offline using low-dimensional-structure self-learning and thresholding reconstruction (LOST) CS reconstruction. Quantitative analysis of PV sharpness and subjective qualitative analysis of overall image quality were performed using a 4-point scale (1: poor; 4: excellent). Results: Quantitative PV sharpness was increased using the proposed approach (0.73 ± 0.09 vs. 0.51 ± 0.07 for the conventional CE-PV MRA protocol, p < 0.001). There were no significant differences in the subjective image quality scores between the techniques (3.32 ± 0.94 vs. 3.53 ± 0.77 using the proposed technique). Conclusions: CS-accelerated free-breathing ECG-triggered CE-PV MRA allows evaluation of PV anatomy with improved sharpness compared to conventional non-ECG gated first-pass CE-PV MRA. This technique may be a valuable alternative for patients in which the first pass CE-PV MRA fails due to inaccurate first pass timing or inability of the patient to perform a 20–25 seconds breath-hold.