Publication:

Home endotoxin exposure and wheeze in infants: correction for bias due to exposure measurement error

Loading...
Thumbnail Image

Date

2005

Published Version

Journal Title

Journal ISSN

Volume Title

Publisher

National Institute of Environmental Health Sciences
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Horick, Nora, Edie Weller, Donald K. Milton, Diane R. Gold, Ruifeng Li, and Donna Spiegelman. 2006. Home endotoxin exposure and wheeze in infants: correction for bias due to exposure measurement error. Environmental Health Perspectives 114(1): 135-140.

Abstract

Exposure to elevated levels of endotoxin in family-room dust was previously observed to be significantly associated with increased wheeze in the first year of life among a cohort of 404 children in the Boston, Massachusetts, metropolitan area. However, it is likely that family-room dust endotoxin was a surrogate for airborne endotoxin exposure. Therefore, a related substudy characterized the relationship between levels of airborne household endotoxin and the level of endotoxin present in house dust, in addition to identifying other significant predictors of airborne endotoxin in the home. We now reexamine the relationship between endotoxin exposure and wheeze under the assumption that the level of airborne endotoxin in the home is the exposure of interest and that the amount of endotoxin in household dust is a surrogate for this exposure. We applied a measurement error correction technique, using all available data to estimate the effect of endotoxin exposure in terms of airborne concentration and accounting for the measurement error induced by using house-dust endotoxin as a surrogate measure in the portion of the data in which airborne endotoxin could not be directly measured. After adjusting for confounding by lower respiratory infection status and race/ethnicity, endotoxin exposure was found to be significantly associated with a nearly 6-fold increase in prevalence of wheeze for a one interquartile range increase in airborne endotoxin (95% confidence interval, 1.2–26) among the 360 children in households with dust endotoxin levels between the 5th and 95th percentiles.

Description

Research Data

Keywords

asthma, endotoxin, measurement error, regression calibration, wheeze, children's health

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories