Publication: Assessing the influence of scanner background noise on auditory processing. I. An fMRI study comparing three experimental designs with varying degrees of scanner noise
Date
2007
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
Wiley-Blackwell
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Gaab, Nadine, John D.E. Gabrieli, and Gary H. Glover. 2007. “Assessing the Influence of Scanner Background Noise on Auditory Processing. I. An fMRI Study Comparing Three Experimental Designs with Varying Degrees of Scanner Noise.” Human Brain Mapping 28 (8): 703–720. doi:10.1002/hbm.20298.
Research Data
Abstract
We compared two experimental designs aimed at minimizing the influence of scanner background noise (SBN) on functional MRI (fMRI) of auditory processes with one conventional fMRI design. Ten subjects listened to a series of four one-syllable words and had to decide whether two of the words were identical. This was contrasted with a no-stimulus control condition. All three experimental designs had a duration of approximately 17 min: 1) a behavior interleaved gradients (BIG; Eden et al. [1999] J Magn Reson Imaging 41:13-20) design (repetition time, TR, = 6 s), where stimuli were presented during the SBN-free periods between clustered volume acquisitions (CVA); 2) a sparse temporal sampling technique (STsamp; e.g., Gaab et al., [2003] Neuroimage 19:1417-1426) acquiring only one set of slices following each of the stimulations with a 16-s TR and jittered delay times between stimulus offset and image acquisition; and 3) an event-related design with continuous scanning (ERcont) using the stimulation design of STsamp but with a 2-s TR. The results demonstrated increased signal within Heschl's gyrus for the STsamp and BIG-CVA design in comparison to ERcont as well as differences in the overall functional anatomy among the designs. The possibility to obtain a time course of activation as well as the full recovery of the stimulus- and SBN-induced hemodynamic response function signal and lack of signal suppression from SBN during the STsamp design makes this technique a powerful approach for conducting auditory experiments using fMRI. Practical strengths and limitations of the three auditory acquisition paradigms are discussed.
Description
Other Available Sources
Keywords
fMRI, auditory cortex, scanner background noise, sparse temporal sampling, lustered volume acquisition
Terms of Use
Metadata Only