Person:

Shao, Peng

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Shao

First Name

Peng

Name

Shao, Peng

Search Results

Now showing 1 - 3 of 3
  • Publication

    High-extinction virtually imaged phased array-based Brillouin spectroscopy of turbid biological media

    (AIP Publishing LLC, 2016) Fiore, Antonio; Zhang, Jitao; Shao, Peng; Yun, Seok Hyun; Scarcelli, Giuliano

    Brillouin microscopy has recently emerged as a powerful technique to characterize the mechanical properties of biological tissue, cell, and biomaterials. However, the potential of Brillouin microscopy is currently limited to transparent samples, because Brillouin spectrometers do not have sufficient spectral extinction to reject the predominant non-Brillouin scattered light of turbid media. To overcome this issue, we combined a multi-pass Fabry-Perot interferometer with a two-stage virtually imaged phased array spectrometer. The Fabry-Perot etalon acts as an ultra-narrow band-pass filter for Brillouin light with high spectral extinction and low loss. We report background-free Brillouin spectra from Intralipid solutions and up to 100 μm deep within chicken muscle tissue.

  • Publication

    Flexible Optical Waveguides for Uniform Periscleral Cross-Linking

    (The Association for Research in Vision and Ophthalmology, 2017) Kwok, Sheldon; Kim, Moonseok; Lin, Harvey H.; Seiler, Theo G.; Beck, Eric; Shao, Peng; Kochevar, Irene; Seiler, Theo; Yun, Seok-Hyun

    Purpose Scleral cross-linking (SXL) with a photosensitizer and light is a potential strategy to mechanically reinforce the sclera and prevent progressive axial elongation responsible for severe myopia. Current approaches for light delivery to the sclera are cumbersome, do not provide uniform illumination, and only treat a limited area of sclera. To overcome these challenges, we developed flexible optical waveguides optimized for efficient, homogeneous light delivery. Methods: Waveguides were fabricated from polydimethylsiloxane elastomer. Blue light (445 nm) is coupled into the waveguide with an input fiber. Light delivery efficiency from the waveguide to scleral tissue was measured and fit to a theoretical model. SXL was performed on fresh porcine eyes stained with 0.5% riboflavin, using irradiances of 0, 25, and 50 mW/cm2 around the entire equator of the eye. Stiffness of scleral strips was characterized with tensiometry. Results: Light delivery with a waveguide of tapered thickness (1.4–0.5 mm) enhanced the uniformity of light delivery, compared to a flat waveguide, achieving a coefficient of variation of less than 10%. At 8% strain, sclera cross-linked with the waveguides at 50 mW/cm2 for 30 minutes had a Young's modulus of 10.7 ± 1.0 MPa, compared to 5.9 ± 0.5 MPa for no irradiation, with no difference in stiffness between proximally and distally treated halves. The stiffness of waveguide-irradiated samples did not differ from direct irradiation at the same irradiance. Conclusions: We developed flexible waveguides for periscleral cross-linking. We demonstrated efficient and uniform stiffening of a 5-mm-wide equatorial band of scleral tissue.

  • Publication

    Effects of Corneal Hydration on Brillouin Microscopy In Vivo

    (The Association for Research in Vision and Ophthalmology, 2018) Shao, Peng; Seiler, Theo G.; Eltony, Amira; Ramier, Antoine; Kwok, Sheldon; Scarcelli, Giuliano; Pineda, Roberto; Yun, Seok-Hyun

    Purpose To investigate how corneal hydration affects the Brillouin frequency of corneal stroma. Methods: From a simple analytical model considering the volume fraction of water in corneal stroma, we derived the dependence of Brillouin frequency on hydration and hydration-induced corneal thickness variation. The Brillouin frequencies of fresh ex vivo porcine corneas were measured as their hydration was varied in dextran solution and water. Healthy volunteers (8 eyes) were scanned in vivo repeatedly over the course of 9 hours, and the diurnal variations of Brillouin frequency and central corneal thickness (CCT) were measured. Results: The measured dependence of Brillouin frequency on hydration, both ex vivo and in vivo, agreed well with the theoretical prediction. The Brillouin frequencies of human corneas scanned immediately after waking were on average ∼25 MHz lower than their daytime average values. For stabilized corneas, the typical variation of Brillouin frequency was ± 7.2 MHz. With respect to CCT increase or swelling, the Brillouin frequency decreased with a slope of −1.06 MHz/μm in vivo. Conclusions: The ex vivo and in vivo data agree with our theoretical model and support that the effect of corneal hydration on Brillouin frequency comes predominantly from the dependence of the tissue compressibility on the water. Corneal hydration correlates negatively with the Brillouin frequency. During daytime activities, the influence of physiological hydration changes in human corneas is < ± 10 MHz. The sensitivity to hydration may potentially be useful in detecting abnormal hydration change in patients with endothelial disorders.