Person: Rutkove, Seward
Email Address
AA Acceptance Date
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
First Name
Name
Search Results
Publication Biomarkers of Sarcopenia in Clinical Trials—Recommendations from the International Working Group on Sarcopenia
(Springer-Verlag, 2012) Cesari, Matteo; Pahor, Marco; Goodpaster, Bret; Hellerstein, Marc; Van Kan, Gabor A.; Anker, Stefan D.; Vrijbloed, J. Willem; Isaac, Maria; Rolland, Yves; M’Rini, Christine; Aubertin-Leheudre, Mylène; Cedarbaum, Jesse M.; Zamboni, Mauro; Sieber, Cornell C.; Laurent, Didier; Evans, William J.; Roubenoff, Ronenn; Morley, John E.; Vellas, Bruno; Fielding, Roger Arthur; Rutkove, SewardSarcopenia, the age-related skeletal muscle decline, is associated with relevant clinical and socioeconomic negative outcomes in older persons. The study of this phenomenon and the development of preventive/therapeutic strategies represent public health priorities. The present document reports the results of a recent meeting of the International Working Group on Sarcopenia (a task force consisting of geriatricians and scientists from academia and industry) held on June 7–8, 2011 in Toulouse (France). The meeting was specifically focused at gaining knowledge on the currently available biomarkers (functional, biological, or imaging-related) that could be utilized in clinical trials of sarcopenia and considered the most reliable and promising to evaluate age-related modifications of skeletal muscle. Specific recommendations about the assessment of aging skeletal muscle in older people and the optimal methodological design of studies on sarcopenia were also discussed and finalized. Although the study of skeletal muscle decline is still in a very preliminary phase, the potential great benefits derived from a better understanding and treatment of this condition should encourage research on sarcopenia. However, the reasonable uncertainties (derived from exploring a novel field and the exponential acceleration of scientific progress) require the adoption of a cautious and comprehensive approach to the subject.
Publication A Technique for Performing Electrical Impedance Myography in the Mouse Hind Limb: Data in Normal and ALS SOD1 G93A Animals
(Public Library of Science, 2012) Li, Jia; Staats, Wayne L.; Spieker, Andrew; Sung, Minhee; Rutkove, SewardObjective: To test a method for performing electrical impedance myography (EIM) in the mouse hind limb for the assessment of disease status in neuromuscular disease models. Methods: An impedance measuring device consisting of a frame with electrodes embedded within an acrylic head was developed. The head was rotatable such that data longitudinal and transverse to the major muscle fiber direction could be obtained. EIM measurements were made with this device on 16 healthy mice and 14 amyotrophic lateral sclerosis (ALS) animals. Repeatability was assessed in both groups. Results: The technique was easy to perform and provided good repeatability in both healthy and ALS animals, with intra-session repeatability (mean ± SEM) of 5% ±1% and 12% ±2%, respectively. Significant differences between healthy and ALS animals were also identified (e.g., longitudinal mean 50 kHz phase was 18±0.6° for the healthy animals and 14±1.0° for the ALS animals, p = 0.0025). Conclusions: With this simple device, the EIM data obtained is highly repeatable and can differentiate healthy from ALS animals. Significance: EIM can now be applied to mouse models of neuromuscular disease to assess disease status and the effects of therapy.
Publication A Comparison of Three Electrophysiological Methods for the Assessment of Disease Status in a Mild Spinal Muscular Atrophy Mouse Model
(Public Library of Science, 2014) Li, Jia; Geisbush, Tom R.; Arnold, William D.; Rosen, Glenn; Zaworski, Phillip G.; Rutkove, SewardObjectives: There is a need for better, noninvasive quantitative biomarkers for assessing the rate of progression and possible response to therapy in spinal muscular atrophy (SMA). In this study, we compared three electrophysiological measures: compound muscle action potential (CMAP) amplitude, motor unit number estimate (MUNE), and electrical impedance myography (EIM) 50 kHz phase values in a mild mouse model of spinal muscular atrophy, the Smn1c/c mouse. Methods: Smn1c/c mice (N = 11) and wild type (WT) animals (−/−, N = 13) were measured on average triweekly until approximately 1 year of age. Measurements included CMAP, EIM, and MUNE of the gastrocnemius muscle as well as weight and front paw grip strength. At the time of sacrifice at one year, additional analyses were performed on the animals including serum survival motor neuron (SMN) protein levels and muscle fiber size. Results: Both EIM 50 kHz phase and CMAP showed strong differences between WT and SMA animals (repeated measures 2-way ANOVA, P<0.0001 for both) whereas MUNE did not. Both body weight and EIM showed differences in the trajectory over time (p<0.001 and p = 0.005, respectively). At the time of sacrifice at one year, EIM values correlated to motor neuron counts in the spinal cord and SMN levels across both groups of animals (r = 0.41, p = 0.047 and r = 0.57, p = 0.003, respectively), while CMAP did not. Motor neuron number in Smn1c/c mice was not significantly reduced compared to WT animals. Conclusions: EIM appears sensitive to muscle status in this mild animal model of SMA. The lack of a reduction in MUNE or motor neuron number but reduced EIM and CMAP values support that much of the pathology in these animals is distal to the cell body, likely at the neuromuscular junction or the muscle itself.
Publication Electrophysiologic Biomarkers for Assessing Disease Progression and the Effect of Riluzole in SOD1 G93A ALS Mice
(Public Library of Science, 2013) Li, Jia; Sung, Minhee; Rutkove, SewardObjective: To compare electrical impedance myography (EIM) 50 kHz phase to weight, motor score, paw grip endurance (PGE), CMAP amplitude, and MUNE for the identification of disease progression and the effect of riluzole in the SOD1 G93A mouse. Methods: Twenty-three animals received 8 mg/kg/day riluzole in the drinking water starting at 6 weeks of age; 22 animals served as controls. Weight, motor score, PGE, CMAP, MUNE, and EIM were performed weekly to evaluate disease progression. Results: No difference in clinical disease onset or survival was found between treated and untreated groups. In addition, all methods failed to identify any beneficial effect of riluzole. Thus, data from all animals were combined for additional analyses. Of the 4 parameters, EIM phase showed the earliest change from baseline and the most linear decline throughout the entire measurement period. In addition, EIM phase correlated with PGE, CMAP amplitude, and MUNE (Spearman r = 0.92, 0.90, and 0.72, respectively, p<0.01 for all). The rate of EIM phase decline also correlated with individual animal survival (Spearman r = −0.31, p<0.05). Conclusions: At this dose, riluzole is ineffective in slowing progression of ALS. However, EIM phase shows early linear declines, supporting its potential as a useful new biomarker for preclinical drug testing.
Publication Guidelines to electrode positioning for human and animal electrical impedance myography research
(Nature Publishing Group, 2016) Sanchez, Benjamin; Pacheck, Adam; Rutkove, SewardThe positioning of electrodes in electrical impedance myography (EIM) is critical for accurately assessing disease progression and effectiveness of treatment. In human and animal trials for neuromuscular disorders, inconsistent electrode positioning adds errors to the muscle impedance. Despite its importance, how the reproducibility of resistance and reactance, the two parameters that define EIM, are affected by changes in electrode positioning remains unknown. In this paper, we present a novel approach founded on biophysical principles to study the reproducibility of resistance and reactance to electrode misplacements. The analytical framework presented allows the user to quantify a priori the effect on the muscle resistance and reactance using only one parameter: the uncertainty placing the electrodes. We also provide quantitative data on the precision needed to position the electrodes and the minimum muscle length needed to achieve a pre-specified EIM reproducibility. The results reported here are confirmed with finite element model simulations and measurements on five healthy subjects. Ultimately, our data can serve as normative values to enhance the reliability of EIM as a biomarker and facilitate comparability of future human and animal studies.
Publication Impaired Distal Thermoregulation in Diabetes and Diabetic Polyneuropathy
(American Diabetes Association, 2009) Rutkove, Seward; Veves, Aristidis; Mitsa, Theophano; Nie, Rui; Fogerson, Patricia M.; Garmirian, Lindsay P.; Nardin, RachelObjective: To determine how thermoregulation of the feet is affected by diabetes and diabetic polyneuropathy in both wakefulness and sleep. Research Design and Methods: Normal subjects, diabetic subjects without neuropathy, diabetic subjects with small-fiber diabetic polyneuropathy, and those with advanced diabetic polyneuropathy were categorized based on neurological examination, nerve conduction studies, and quantitative sensory testing. Subjects underwent foot temperature monitoring using an iButton device attached to the foot and a second iButton for recording of ambient temperature. Socks and footwear were standardized, and subjects maintained an activity diary. Data were collected over a 32-h period and analyzed. Results: A total of 39 normal subjects, 28 patients with diabetes but without diabetic polyneuropathy, 14 patients with isolated small-fiber diabetic polyneuropathy, and 27 patients with more advanced diabetic polyneuropathy participated. No consistent differences in foot temperature regulation between the four groups were identified during wakefulness. During sleep, however, multiple metrics revealed significant abnormalities in the diabetic patients. These included reduced mean foot temperature (P < 0.001), reduced maximal temperature (P < 0.001), increased rate of cooling (P < 0.001), as well as increased frequency of variation (P = 0.005), supporting that patients with diabetic polyneuropathy and even those with only diabetes but no diabetic polyneuropathy have impaired nocturnal thermoregulation. Conclusions: Nocturnal foot thermoregulation is impaired in patients with diabetes and diabetic polyneuropathy. Because neurons are highly temperature sensitive and because foot warming is part of the normal biology of sleep onset and maintenance, these findings suggest new potentially treatable mechanisms of diabetes-associated nocturnal pain and sleep disturbance.
Publication Intraspinal Neural Stem Cell Transplantation in Amyotrophic Lateral Sclerosis: Phase 1 Trial Outcomes
(BlackWell Publishing Ltd, 2014) Feldman, Eva L; Boulis, Nicholas M; Hur, Junguk; Johe, Karl; Rutkove, Seward; Federici, Thais; Polak, Meraida; Bordeau, Jane; Sakowski, Stacey A; Glass, Jonathan DObjective: The US Food and Drug Administration–approved trial, “A Phase 1, Open-Label, First-in-Human, Feasibility and Safety Study of Human Spinal Cord-Derived Neural Stem Cell Transplantation for the Treatment of Amyotrophic Lateral Sclerosis, Protocol Number: NS2008-1,” is complete. Our overall objective was to assess the safety and feasibility of stem cell transplantation into lumbar and/or cervical spinal cord regions in amyotrophic lateral sclerosis (ALS) subjects. Methods: Preliminary results have been reported on the initial trial cohort of 12 ALS subjects. Here, we describe the safety and functional outcome monitoring results for the final trial cohort, consisting of 6 ALS subjects receiving 5 unilateral cervical intraspinal neural stem cell injections. Three of these subjects previously received 10 total bilateral lumbar injections as part of the earlier trial cohort. All injections utilized a novel spinal-mounted stabilization and injection device to deliver 100,000 neural stem cells per injection, for a dosing range up to 1.5 million cells. Subject assessments included detailed pre- and postsurgical neurological outcome measures. Results: The cervical injection procedure was well tolerated and disease progression did not accelerate in any subject, verifying the safety and feasibility of cervical and dual-targeting approaches. Analyses on outcome data revealed preliminary insight into potential windows of stem cell biological activity and identified clinical assessment measures that closely correlate with ALS Functional Rating Scale-Revised scores, a standard assessment for ALS clinical trials. Interpretation This is the first report of cervical and dual-targeted intraspinal transplantation of neural stem cells in ALS subjects. This approach is feasible and well-tolerated, supporting future trial phases examining therapeutic dosing and efficacy.
Publication Critically Re-Evaluating a Common Technique: Accuracy, Reliability, and Confirmation Bias of EMG
(Ovid Technologies (Wolters Kluwer Health), 2015) Narayanaswami, Pushpa; Geisbush, Thomas; Jones, Lyell; Weiss, Michael; Mozaffar, Tahseen; Gronseth, Gary; Rutkove, SewardObjectives: (1) To assess the diagnostic accuracy of EMG in radiculopathy. (2) To evaluate the intrarater reliability and interrater reliability of EMG in radiculopathy. (3) To assess the presence of confirmation bias in EMG. Methods: Three experienced academic electromyographers interpreted 3 compact discs with 20 EMG videos (10 normal, 10 radiculopathy) in a blinded, standardized fashion without information regarding the nature of the study. The EMGs were interpreted 3 times (discs A, B, C) 1 month apart. Clinical information was provided only with disc C. Intrarater reliability was calculated by comparing interpretations in discs A and B, interrater reliability by comparing interpretation between reviewers. Confirmation bias was estimated by the difference in correct interpretations when clinical information was provided. Results: Sensitivity was similar to previous reports (77%, confidence interval [CI] 63%–90%); specificity was 71%, CI 56%–85%. Intrarater reliability was good (κ 0.61, 95% CI 0.41–0.81); interrater reliability was lower (κ 0.53, CI 0.35–0.71). There was no substantial confirmation bias when clinical information was provided (absolute difference in correct responses 2.2%, CI −13.3% to 17.7%); the study lacked precision to exclude moderate confirmation bias. Conclusions: This study supports that (1) serial EMG studies should be performed by the same electromyographer since intrarater reliability is better than interrater reliability; (2) knowledge of clinical information does not bias EMG interpretation substantially; (3) EMG has moderate diagnostic accuracy for radiculopathy with modest specificity and electromyographers should exercise caution interpreting mild abnormalities. Classification of evidence: This study provides Class III evidence that EMG has moderate diagnostic accuracy and specificity for radiculopathy.
Publication Electrical impedance myography as a biomarker to assess ALS progression
(Informa UK Limited, 2012) Rutkove, Seward; Caress, James B.; Cartwright, Michael S.; Burns, Ted M.; Warder, Judy; David, William; Goyal, Namita; Maragakis, Nicholas J.; Clawson, Lora; Benatar, Michael; Usher, Sharon; Sharma, Khema R.; Gautam, Shiva; Narayanaswami, Pushpa; Raynor, Elizabeth; Watson, Mary Lou; Shefner, Jeremy M.Electrical impedance myography (EIM), a non-invasive, electrophysiological technique, has preliminarily shown value as an ALS biomarker. Here we perform a multicenter study to further assess EIM’s potential for tracking ALS. ALS patients were enrolled across eight sites. Each subject underwent EIM, handheld dynamometry (HHD), and the ALS Functional Rating Scale-revised (ALSFRS-R) regularly. Techniques were compared by assessing the coefficient of variation (CoV) in the rate of decline and each technique’s correlation to survival. Results showed that in the 60 patients followed for one year, EIM phase measured from the most rapidly progressing muscle in each patient had a CoV in the rate of decline of 0.62, compared to HHD (0.82) and the ALSFRS-R (0.74). Restricting the measurements to the first six months gave a CoV of 0.55 for EIM, 0.93 for HHD, and 0.84 for ALSFRS-R. For both time-periods, all three measures correlated with survival. Based on these data, a six-month clinical trial designed to detect a 20% treatment effect with 80% power using EIM would require only 95 patients/arm compared to the ALSFRS-R, which would require 220 subjects/arm. In conclusion, EIM can serve as a useful ALS biomarker that offers the prospect of greatly accelerating phase 2 clinical trials.
Publication The effect of subacute denervation on the electrical anisotropy of skeletal muscle: Implications for clinical diagnostic testing
(Elsevier BV, 2010) Ahad, Mohammad A.; Narayanaswami, Pushpa; Kasselman, Lora J.; Rutkove, SewardObjective
Applied electrical current flows preferentially along rather than across muscle fibers, a characteristic called anisotropy. In this study, we investigate the alteration in muscle anisotropy after denervation.
Methods
Eight adult male rats underwent sciatic nerve crush and the gastrocnemius was harvested from 1 to 2.5 weeks later. Muscle from 12 additional healthy rats was also obtained. Multifrequency electrical impedance measurements were made on the tissue and its conductivity and relative permittivity (i.e., its polarizability) calculated. Anisotropy of the tissue was determined by calculating conductivity and permittivity differences, subtracting transverse from longitudinal values. Muscle fiber and blood vessel quantification were also performed.
Results
The mean conductivity difference for sciatic crush animals was higher (p <0.05) than for the healthy animals across the frequency spectrum, due to a greater increase in longitudinal conductivity than in transverse conductivity. For example, at 10 kHz, the conductivity difference was 0.15 S/m for healthy animals and 0.29 S/m for post-crush animals. Relative permittivity difference values, however, were similar between groups. There was a strong correlation of conductivity anisotropy to muscle fiber size but not to blood vessel area.
Conclusions
Anisotropy of muscle conductivity increases markedly after subacute denervation injury.
Significance
This alteration in anisotropy has direct relevance to the clinical application of electrical impedance myography. We also speculate that it may impact other forms of diagnostic testing, including needle electromyography and magnetic resonance imaging.