Person: Li, Chih-Hao
Email Address
AA Acceptance Date
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
First Name
Name
Search Results
Publication Calibration of an Astrophysical Spectrograph Below 1 m/s Using a Laser Frequency Comb
(Optical Society of America, 2012) Phillips, David; Glenday, Alexander; Li, Chih-Hao; Cramer, Claire; Furesz, Gabor; Chang, Guoqing; Benedick, Andrew J.; Chen, Li-Jin; Szentgyorgyi, Andrew; Walsworth, RonaldWe deployed two wavelength calibrators based on laser frequency combs (“astro-combs”) at an astronomical telescope. One astro- comb operated over a 100 nm band in the deep red (∼ 800 nm) and a second operated over a 20 nm band in the blue (∼ 400 nm). We used these red and blue astro-combs to calibrate a high-resolution astrophysical spectrograph integrated with a 1.5 m telescope, and demonstrated calibration precision and stability sufficient to enable detection of changes in stellar radial velocity < 1 m/s.
Publication Optimization of Filtering Schemes for Broadband Astro-Combs
(Optical Society of America, 2012) Chang, Guoqing; Li, Chih-Hao; Phillips, David; Szentgyorgyi, Andrew; Walsworth, Ronald; Kärtner, Franz X.To realize a broadband, large-line-spacing astro-comb, suitable for wavelength calibration of astrophysical spectrographs, from a narrowband, femtosecond laser frequency comb (“source-comb”), one must integrate the source-comb with three additional components: (1) one or more filter cavities to multiply the source-comb’s repetition rate and thus line spacing; (2) power amplifiers to boost the power of pulses from the filtered comb; and (3) highly nonlinear optical fiber to spectrally broaden the filtered and amplified narrowband frequency comb. In this paper we analyze the interplay of Fabry-Perot (FP) filter cavities with power amplifiers and nonlinear broadening fiber in the design of astro-combs optimized for radial-velocity (RV) calibration accuracy. We present analytic and numeric models and use them to evaluate a variety of FP filtering schemes (labeled as identical, co-prime, fraction-prime, and conjugate cavities), coupled to chirped-pulse amplification (CPA). We find that even a small nonlinear phase can reduce suppression of filtered comb lines, and increase RV error for spectrograph calibration. In general, filtering with two cavities prior to the CPA fiber amplifier outperforms an amplifier placed between the two cavities. In particular, filtering with conjugate cavities is able to provide <1 cm/s RV calibration error with >300 nm wavelength coverage. Such superior performance will facilitate the search for and characterization of Earth-like exoplanets, which requires <10 cm/s RV calibration error.