Publication Varying negative work assistance at the ankle with a soft exosuit during loaded walking
(BioMed Central, 2017) Malcolm, Philippe; Lee, Sangjun; Crea, Simona; Siviy, Christopher; Saucedo, Fabricio; Galiana, Ignacio; Panizzolo, Fausto Antonio; Holt, Kenneth G.; Walsh, ConorBackground: Only very recently, studies have shown that it is possible to reduce the metabolic rate of unloaded and loaded walking using robotic ankle exoskeletons. Some studies obtained this result by means of high positive work assistance while others combined negative and positive work assistance. There is no consensus about the isolated contribution of negative work assistance. Therefore, the aim of the present study is to examine the effect of varying negative work assistance at the ankle joint while maintaining a fixed level of positive work assistance with a multi-articular soft exosuit. Methods: We tested eight participants during walking at 1.5 ms−1 with a 23-kg backpack. Participants wore a version of the exosuit that assisted plantarflexion via Bowden cables tethered to an off-board actuation platform. In four active conditions we provided different rates of exosuit bilateral ankle negative work assistance ranging from 0.015 to 0.037 W kg−1 and a fixed rate of positive work assistance of 0.19 W kg−1. Results: All active conditions significantly reduced metabolic rate by 11 to 15% compared to a reference condition, where the participants wore the exosuit but no assistance was provided. We found no significant effect of negative work assistance. However, there was a trend (p = .08) toward greater reduction in metabolic rate with increasing negative work assistance, which could be explained by observed reductions in biological ankle and hip joint power and moment. Conclusions: The non-significant trend of increasing negative work assistance with increasing reductions in metabolic rate motivates the value in further studies on the relative effects of negative and positive work assistance. There may be benefit in varying negative work over a greater range or in isolation from positive work assistance. Electronic supplementary material The online version of this article (doi:10.1186/s12984-017-0267-5) contains supplementary material, which is available to authorized users.
Publication Effect of timing of hip extension assistance during loaded walking with a soft exosuit
(BioMed Central, 2016) Ding, Ye; Panizzolo, Fausto Antonio; Siviy, Christopher; Malcolm, Philippe; Galiana, Ignacio; Holt, Kenneth G.; Walsh, ConorBackground: Recent advances in wearable robotic devices have demonstrated the ability to reduce the metabolic cost of walking by assisting the ankle joint. To achieve greater gains in the future it will be important to determine optimal actuation parameters and explore the effect of assisting other joints. The aim of the present work is to investigate how the timing of hip extension assistance affects the positive mechanical power delivered by an exosuit and its effect on biological joint power and metabolic cost during loaded walking. In this study, we evaluated 4 different hip assistive profiles with different actuation timings: early-start-early-peak (ESEP), early-start-late-peak (ESLP), late-start-early-peak (LSEP), late-start-late-peak (LSLP). Methods: Eight healthy participants walked on a treadmill at a constant speed of 1.5 m · s-1 while carrying a 23 kg backpack load. We tested five different conditions: four with the assistive profiles described above and one unpowered condition where no assistance was provided. We evaluated participants’ lower limb kinetics, kinematics, metabolic cost and muscle activation. Results: The variation of timing in the hip extension assistance resulted in a different amount of mechanical power delivered to the wearer across conditions; with the ESLP condition providing a significantly higher amount of positive mechanical power (0.219 ± 0.006 W · kg-1) with respect to the other powered conditions. Biological joint power was significantly reduced at the hip (ESEP and ESLP) and at the knee (ESEP, ESLP and LSEP) with respect to the unpowered condition. Further, all assistive profiles significantly reduced the metabolic cost of walking compared to the unpowered condition by 5.7 ± 1.5 %, 8.5 ± 0.9 %, 6.3 ± 1.4 % and 7.1 ± 1.9 % (mean ± SE for ESEP, ESLP, LSEP, LSLP, respectively). Conclusions: The highest positive mechanical power delivered by the soft exosuit was reported in the ESLP condition, which showed also a significant reduction in both biological hip and knee joint power. Further, the ESLP condition had the highest average metabolic reduction among the powered conditions. Future work on autonomous hip exoskeletons may incorporate these considerations when designing effective control strategies. Electronic supplementary material The online version of this article (doi:10.1186/s12984-016-0196-8) contains supplementary material, which is available to authorized users.
Publication Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
(American Association for the Advancement of Science (AAAS), 2017) Quinlivan, Brendan; Lee, S.; Malcolm, Philippe; Rossi, D. M.; Grimmer, M.; Siviy, Christopher; Karavas, Nikolaos; Wagner, D.; Asbeck, A.; Galiana Bujanda, Ignacio; Walsh, ConorWhen defining requirements for any wearable robot for walking assistance it is paramount to maximize the user’s net metabolic benefit, while limiting the metabolic penalty of carrying the system’s mass. Thus, the aim of this study was to isolate and characterize the relationship between assistance magnitude and the metabolic cost of walking while also examining changes to the wearer’s underlying gait mechanics. The study was performed with a tethered multiarticular soft exosuit during normal walking where assistance was directly applied at the ankle joint and indirectly at the hip due to a textile architecture. The exosuit controller was designed such that the delivered torque profile at the ankle joint approximated that of the biological torque during normal walking. Seven subjects walked on a treadmill at 1.5 m s-1 in one unpowered and four powered conditions where the peak moment applied at the ankle joint was varied from approximately 10% to 38% of biological ankle moment (equivalent to an applied force of 18.7% to 75.0% of body weight). Results showed that with increasing peak exosuit ankle moment, net metabolic rate continually decreased within the tested range. When maximum assistance was applied, the metabolic rate of walking was reduced by 22.83 ± 3.17% relative to the powered-off condition (mean ± s.e.m.).