Publication:

A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking

Loading...
Thumbnail Image

Date

2016

Journal Title

Journal ISSN

Volume Title

Publisher

Springer Nature
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Panizzolo, Fausto A., Ignacio Galiana, Alan T. Asbeck, Christopher Siviy, Kai Schmidt, Kenneth G. Holt, and Conor J. Walsh. 2016. “A Biologically-Inspired Multi-Joint Soft Exosuit That Can Reduce the Energy Cost of Loaded Walking.” J NeuroEngineering Rehabil 13 (1) (May 12). doi:10.1186/s12984-016-0150-9.

Abstract

Background: Carrying load alters normal walking, imposes additional stress to the musculoskeletal system, and results in an increase in energy consumption and a consequent earlier onset of fatigue. This phenomenon is largely due to increased work requirements in lower extremity joints, in turn requiring higher muscle activation. The aim of this work was to assess the biomechanical and physiological effects of a multi-joint soft exosuit that applies assistive torques to the biological hip and ankle joints during loaded walking. Methods: The exosuit was evaluated under three conditions: powered (EXO_ON), unpowered (EXO_OFF) and unpowered removing the equivalent mass of the device (EXO_OFF_EMR). Seven participants walked on an instrumented split-belt treadmill and carried a load equivalent to 30% their body mass. We assessed their metabolic cost of walking, kinetics, kinematics, and lower limb muscle activation using a portable gas analysis system, motion capture system, and surface electromyography. Results: Our results showed that the exosuit could deliver controlled forces to a wearer. Net metabolic power in the EXO_ON condition (7.5±0.6 W kg-1) was 7.3±5.0% and 14.2±6.1% lower than in the EXO_OFF_EMR condition (7.9 ±0.8 W kg-1; p = 0.027) and in the EXO_OFF condition (8.5±0.9W kg-1; p = 0.005), respectively. The exosuit also reduced the total joint positive biological work (sum of hip, knee and ankle) when comparing the EXO_ON condition (1.06±0.16 J kg-1) with respect to the EXO_OFF condition (1.28±0.26 J kg-1; p = 0.020) and to the EXO_OFF_EMR condition (1.22±0.21 J kg-1; p = 0.007). Conclusions: The results of the present work demonstrate for the first time that a soft wearable robot can improve walking economy. These findings pave the way for future assistive devices that may enhance or restore gait in other applications.

Description

Other Available Sources

Research Data

Keywords

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories